DMX-512 connection / connection between fixtures
The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.
Please note, the starting address depends upon which controller is being used.
Only use a DMX-cable and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture
or one fixture with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated. Plug the terminator with a 120
resistor
between Signal (–) and Signal (+) in the DMX-output of the last fixture.
Master/Slave operation
The master/slave operation enables that several devices can be synchronized and controlled by one master
device.
On the rear panel of the device you can find an XLR jack and an XLR plug, which can be used for
connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX cable. Connect the OUT jack
with the IN plug of the next device.
Set DIP Switch 10 to OFF in order to determine the Master device. Set DIP Switch 1 and 10 to ON in order to
determine the Slave device.