Jackson AIRMAX+ Manual De Instrucciones página 3

Respirador purificador eléctrico de aire
Ocultar thumbs Ver también para AIRMAX+:
REGULATORY COMPLIANCE AND MARKINGS
P R SL-Filter AIRMAX
Filter colour coding
Manufacturer
Compliance
CE:
Module B, C2 Audit conducted by
UKCA:
Module B, C2 Audit conducted by
Markings
WARNINGS AND LIMITATIONS OF USE
• This PAPR is not suitable for work in poorly ventilated areas (i.e. confined spaces) where oxygen level is
suspected to be below 17%.
• Determination of the use of this PAPR system should be addressed by a trained health and safety officer
that determines the suitability of the protection offered by this device for the particular task and the
hazards involved.
• Do not use this respiratory device when the concentration of hazardous substances has not been deter-
mined and their impact on human health and safety by a trained health and safety officer.
• The wearer of this respiratory system must have read this manual and fully understood the functions and
settings on the AIRMAX+ PAPR system. Its use, cleaning, maintenance, disinfection and storage condi-
tions should follow the instructions provided in this manual. Products returned for warranty replacement
will only be considered for replacement only if all recommendations provided in this manual were fully
followed.
• Do not use the AIRMAX+ PAPR system in areas were explosions might occur. Avoid direct exposure to
flames and/or sparks. Do not use the AIRMAX+ PAPR system in the presence of strong winds.
• Use only original filters certified for EN 12941:1998+A1:2003+A2:2008 TH3 P R SL the particular respira-
tory system.
• If the blower unit acoustic alarm sounds please leave immediately the working area and enter a non-
contaminated environment.
• Do not store nor use this respiratory system under temperature conditions that exceed recommendations
of this manual (below -5°C and above +55°C).
• Particle filters are not suitable to provide protection against gases and vapours above occupational
exposure limits. Please use TH3 P R SL filters packed in original packaging only, unsealed or second-hand
products must not be used.
• Carefully review the sealing gasket and search for any visible damage. Do not use if its serviceability is
suspected to be affected. Only use particle filters produced by Surewerx USA Inc properly labelled and
packed.
• Do not attempt to touch or modify the components of this PAPR.
• At very high work rates the pressure in the device may become negative at peak inhalation flow.
• JACKSON SAFETY AIRMAX+ PAPR systems are for use only by competent, trained personnel.
• Make sure that the air hose doesn`t make a loop and does not get caught up on something in the work
environment.
Product code 40302
White (background)
Surewerx USA Inc
Elgin IL USA 60123
EN 2941:1998+A1:2003+A2:2008 TH3 P R SL
OCCUPATIONAL SAFETY RESEARCH INSTITUTE, V.V.I.
Notified body 1024
Jeruzalémská 1283/9, 110 00 Praha 1, Czech Republic
UL INTERNATIONAL (UK) LTD
Approved body 0843
Unit 1-3 Horizon Kingsland, Business Park Wade Road, Basingstoke
RG24 8AH, United Kingdom
See labels on product components
3
loading

Este manual también es adecuado para: