stops providing power to the battery this allows the battery to be charged overnight. It is not recommended
to charge batteries for extreme lengths of time as this can reduce the batteries capacity.
REMOVING AND REPLACING THE BATTERY
Hold the motor unit with the hose outlet down (in a
clean area away for contaminants) carefully pull the
battery tab towards the middle. Lift the battery up at
the catch end and the battery will now come free. To
replace the battery, place it into the cavity sliding the
non-catch end in first into the location groove. Then
push the battery down ensuring to get a firm click.
STORAGE AND TRANSPORTATION
When not in use or during transportation the blower
and head units should be stored in the container in
which they were supplied, in a place away from direct sunlight and contact with solvents or other surfaces or
objects that may impact and damage them. Do not store in areas with extreme temperature (outside -5°C to
+55°C range) or humidity (above 75%RH) conditions.
USER INSTRUCTION MANUAL FOR THE AIRMAX+ PAPR BATTERY CHARGER
Component code – 40363
This charger complies with the European regulations. Please read and keep these instructions carefully,
they contain important operation and safety descriptions. If the charger is not used in accordance with this
manual you may risk causing a fire, personal injury or equipment damage. Check label on the rear of the
charger for further details.
Features
The AIRMAX+ PAPR charger is suitable for Lithium-ion battery packs only and has been provided with a short
circuit protection device. Each charger has quick-change socket power adapter for various mains (see
picture below). It is designed to quick charge 4-6 cells Lithium–Ion battery packs with a capacity of
5200mAh to 7800mAh.
AIRMAX CHARGER -40363
Only use this charger with batteries that meet the specifications on the chart below: Connect its DC output
plug to the battery and then connect its AC input plug to 100- 240VAC mains power before switching on the
mains power point; ensure the charging lights are illuminated.
It is normal that the charger and the battery might warm up (below 50°C) during charging; otherwise please stop
using it. Please disconnect the charger AC input plug first and then disconnect the DC output plug when charging
is finished. The red LED shows that the batteries are still charging. The green LED indicates that the battery is
fully charged and ready for use. Do not leave the battery charger in the power supply when not in use.
TECHNICAL SPECIFICATIONS
• Operational range: 100Vac – 240Vac
• Frequency: 50-60Hz at 150mA
• Operating temperature range: 0°C to 40°C
• Operating relative humidity: 8% to 85%
• Operating temperature range: 0°C to 40°C
• Initial charge before first use of batteries: 8 hours