WIRING SCHEMATIC
Black (line)
White (line)
Yellow / Green (ground)
Photocell is installed in the access side knockout location and connected as per the wiring diagram
DISABLE PHOTOCELL
Photocell is installed in the access side knockout location
and connected as per the wiring diagram.
To disable photocell, open fixture cover and unplug photo-
cell wire connector.
ADJUST POWER & CCT
With a #2 Phillips screwdriver, loosen
the cover screws.
3
©2022 EiKO Global, LLC. World Headquarters: 18000 W. 105
SWP1 Driver
Head Office, Canada: 80-86 Carrier Drive Toronto, ON Canada M9W 5R1 (P) 1.888.741.2673 (F) 1.888.705.1335
Power
Select
Select
Switches
MOVE PHOTOCELL
To move photocell to an alternate 1/2" threaded knockout location,
disconnect photocell connector and gently unscrew and retain
the photocell. Remove the 1/2" threaded knockout from the new
alternate location and use it to fill the original photocell location.
Gently screw photocell into the new location and reattach photocell
connector.
Adjust power and/or CCT and once selected
close cover and tighten screws.
Note: Default power setting is max wattage for
all models.
Note: Default CCT setting is 4000K for all
models.
Street, 3
Floor, Olathe, KS 66061 (P) 1.800.852.2217 (F) 1.800.492.8975
th
rd
Purple (Dim+)
0-10V
Pink (Dim-/12V-)
Dimmer
&
CCT
*Optional
To LED's
Photocell and Connector
eiko.com