- ITC mode operation and control mode table
(in Eco Mode, the compressor is limited to 2500 rpm)
o Key:
•
•
•
TAB.02
9.9 < V < 11.2
11.2 < V < 12.4
21.6 < V < 23.0
23.0 < V < 24.1
46
COMPRESSOR OFF, indicates compressor status [Off] the moment
you enter the specified voltage range.
COMPRESSOR ON, indicates compressor status [On] the moment
you enter the specified voltage range.
RPM, indicates the number of revolutions in which the compressor
can be found in reference to compressor status and to power
voltage.
- - -
12Vdc
V < 9.9
V < 12.4
24Vdc
V < 21.6
V < 24.1
ISOTHERM Digital Display
Compressor Status
Compressor
Compressor
Off
RPM
0
0
2500
2500 - 3500
3500
RPM
0
0
2500
2500 - 3500
3500
On
RPM
0
2500
3500
RPM
0
2500
3500