Storage/winter protection
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
• Thoroughly clean the unit.
• Check the unit for damage and replace damaged components.
• Store the pump submerged and in a frost-free environment.
• Protect electrical connections from moisture and dirt.
Malfunction remedy
Malfunction
Pump does not start
Pump does not deliver or the delivered
quantity is insufficient
Skimmer floats up
Technical data
Unit data
Pond and Pool Skimmer PPS 12V
Max. power consumption
Max. pond surface
Weight
PRI
Rated voltage
Mains frequency
SEC
Output voltage
Output frequency
Protection class
Length mains connection cable
Rated voltage
Protection class
Max. immersion depth
Max. flow rate
Length connection cable
Permissible water quality
Type
pH value
Hardness
Free chlorine
Chloride content
Salt content
Overall dry residue
Temperature
12
Probable cause
No mains voltage
Transformer defective
Filter basket soiled
Foam filter clogged
Impeller unit soiled
Impeller unit worn
Foam filter clogged
W
35
20
kg
4.1
V AC
230
Hz
50
V AC
12
Hz
50
IP44
m
2
V AC
12
IP68
m
4
l/h
2000
m
8
DH
mg/l
mg/l
%
mg/l
°C
Remedy
Check the mains voltage and the supply lines
Replace transformer
Clean filter basket
Clean the foam filter
Clean impeller unit
Replace impeller unit
Clean foam filter
Fresh water, pond water
6.8 ... 8.5
8 ... 15
<0.3
<250
<0.4
<50
+4 ... +35
Pool water
7.2 ... 8.3
8 ... 15
<0.6
<250
<0.4
<50
+4 ... +30