INSTALLATION
only intended for qualified personnel
Before installing the hood, carefully read the chapter 'SAFETY IN-
STRUCTIONS AND WARNINGS' .
TECHNICAL FEATURES
The technical specifications are exhibited on the labels located inside the hood.
POSITIONING
The minimum distance between the highest part of the cooking equipment and the
lowest part of the hood is indicated in the installation instructions.
Generally, when the hood is placed over gas cookers, the distance must be at least 65 cm
(25.6''). However, according to an interpretation of standard EN60335-2-31 dated 11-07-
2002 of TC61 (sub-clause 7.12.1 meeting 15 agenda item 10.11), the minimum distance
between the cooker and lower part of the hood can be reduced to the quota reported in
the installation instructions.
Should the instructions for the gas cooker specify a greater distance, this must be taken
into consideration.
Do not install the hood outdoors and do not expose it to outdoor environment (rain, wind,
etc.).
ELECTRICAL CONNECTION
(only intended for qualified personnel)
Disconnect the equipment from electrical mains power supply before carry-
ing out any operations on the hood.
Ensure that the wires inside the hood are not disconnected or cut:
in the event of damage, contact your nearest Servicing Department.
Refer to qualified personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law in force.
Before connecting the hood to the electrical mains power supply, check that:
voltage supply corresponds with what is reported on the data plate located inside the
hood;
the electrical system is compliant and can withstand the load (see the technical specifi-
cations located inside the hood);
the power supply plug and cable do not come into contact with temperatures exceed-
ing 70 °C;
the power supply system is effectively and properly connected to earth in compliance
with regulations in force;
the socket used to connect the hood is within reach.
In case of:
devices fitted with cables without a plug: the type of plug to use is a ''standardised'' one.
The wires must be connected as follows: yellow-green for earthing, blue for neutral and
brown for the phase. The plug must be connected to an adequate safety socket.
fixed equipment not provided with a power supply cable and plug, or any other device
that ensures disconnection from the electrical mains, with an opening gap of the con-
tacts that enables total disconnection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power supply in compliance
with installation regulations.
The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety regulations.
FUMES DISCHARGE
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this model, the air passes through the zeolite-carbon filters to be
purified and recycled in the environment.
Ensure that the active carbon filters are assembled into the hood, if not,
install them as indicated in the assembly instructions.
In this version the check valve must not be assembled: remove it if it is on the air
outlet fitting of the motor.
ASSEMBLY INSTRUCTIONS
only intended for qualified personnel
The hood can be installed in various configurations.
The generic assembly steps apply to all installations; for each case, follow
the specific steps provided for the required installation.
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct fumes and vapours
towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours and odours.
By means of the Timer function, it is possible to set auto switch-off function which will allow
the hood to turn off automatically after 15 minutes of operation.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal filters must be cleaned every 30 hours of operation.
The zeolite-carbon filters must be reactivated every 18 months and replaced every 3 years.
For further details see the "MAINTENANCE" chap.
ELECTRONIC PUSHBUTTON PANEL
Brief
Motor ON/OFF
pressure
Upon start-up, the speed is that stored at the previous op-
eration.
Increase speed
from 1 to 4
Brief
Speed 4 is only active
pressure
for a few minutes,
then speed 3 acti-
vates.
Brief
Reduce speed from
pressure
4 to 1
Lifting the hood
Activated only with the fan not working.
Prolonged
Stop:
pressure
- when the upper microswitch is reached
- pressing the + or - button.
Lowering the hood
Activated only with the fan not working.
Prolonged
Stop:
pressure
- when the lower microswitch is reached
- pressing the + or - button.
Brief
Light on/off
pressure
Prolonged
Change light tone from 2700K to 5600K
pressure
TIMER
Auto switch-off after 15 min.
Brief
The function deactivates (red LED off ) if:
pressure
- The TIMER key (
- The ON/OFF key (
12
The speeds are indicated by the
LEDs on the keys:
Speed 1
Speed 2
Speed 3
Speed 4
("+" LED flashing)
) is pressed again.
) is pressed.