Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

All manuals and user guides at all-guides.com
Limited One Year Warranty
T&S warrants to the original purchaser (other than
for purposes of resale) that such product is free from
defects in material and workmanship for a period of
one (1) year from the date of purchase. During this
one-year warranty period, if the product is found to
be defective, T&S shall, at its options, repair and/
or replace it. To obtain warranty service, products
must be returned to...
T&S Brass and Bronze Works, Inc.
Attn: Warranty Repair Department
2 Saddleback Cove
Travelers Rest, SC 29690
Shipping, freight, insurance, and other transpor-
tation charges of the product to T&S and the return
of repaired or replaced product to the purchaser are
the responsibility of the purchaser. Repair and/or
replacement shall be made within a reasonable time
after receipt by T&S of the returned product. This
warranty does not cover Items which have received
secondary finishing or have been altered or modi-
fied after purchase, or for defects caused by physi-
cal abuse to or misuse of the product, or shipment
of the products.
Any express warranty not provided herein, and
any remedy for Breach of Contract which might arise,
is hereby excluded and disclaimed. Any implied
warranties of merchantability or fitness for a particu-
lar purpose are limited to one year in duration. Under
no circumstances shall T&S be liable for loss of
use or any special consequential costs, expenses
or damages.
Some states do not allow limitations on how long
and implied warranty lasts or the exclusion or limi-
tation of incidental or consequential damages, so
the above limitations or exclusions may not apply
to you. Specific rights under this warranty and other
rights vary from state to state.
P/N: 098-009549-45 Rev.3
Date: 980120
Drawn: CW
Checked: JLT
4-14-98
Approved: MW
4-14-98
Installation and
Maintenance
Instructions
ATMOSPHERIC
VACUUM BREAKERS
B-0968 (3/8") & B-0969 (1/2")
(Also use for replacement parts,
B-0968-RK01 3/8" & B-0969-RK01 1/2")
Deutsch:
Español:
Français:
Installations- und
Wartungsanleitungen
la Instalación y las
Instrucciones de
Mantenimiento
les Instructions
d'Installation et
d'Entretien
loading

Resumen de contenidos para T&S B-0968

  • Página 1 Any express warranty not provided herein, and B-0968 (3/8”) & B-0969 (1/2”) any remedy for Breach of Contract which might arise, is hereby excluded and disclaimed. Any implied...
  • Página 2 All manuals and user guides at all-guides.com Exploded View...
  • Página 3 All manuals and user guides at all-guides.com Part Number Guide Vacuum Breaker Assemblies & Kit Screw, Self-tapping V.B. Namplate (3/8" or 1/2") Coverplate (3/8" or 1/2") Repair Kit 3/8" V.B. B-0968-RK01 Insert 009785-45 O'-Ring, Insert O'-Ring, Plunger 001066-45 Piston (3/8" V.B.) 009525-45 Repair Kit 1/2"...
  • Página 4 All manuals and user guides at all-guides.com Typical Installation: Note: Where the device is a separate unit, in the absence of a Single Vacuum Breaker Critical Installation Level (CIL) mark, the extreme bottom of the 1. Vacuum breaker must be installed no.9 casting should be used to with the supply connected to the determine its installed position.
  • Página 5 All manuals and user guides at all-guides.com Typical Installation: B-0968-RK01 (Kit) B-0969-RK01 (Kit) 3/8” Vac. Breaker 1/2” Vac. Breaker Follow the instructions in the Single Vacuum Breaker section, Step 1 thru step 5. Two typical T&S unit installations will look as follows:...
  • Página 6 All manuals and user guides at all-guides.com Instalación Típica: Nota: Donde el aparato sea una unidad separada, en la ausencia de Anti-sifón singular la marca (CIL) que significa nivel crítico de instalación, el lado 1. La válvula anti-sifón tiene que ser extremo posterior de la parte No.9 instalada, con la fuente surtidora en la debe ser utilizado para determinar...
  • Página 7 1 al 5. 4. Reemplaze con partes nuevas del estuche de reparo. Dos instalaciones de unidades tipicas de T&S se verán como lo siguiente: B-0968-RK01 3/8” B-0969-RK01 1/2” Válvula Anti-sifón Válvula Anti-sifón B-929 Ensamblado De Válvula Anti-sifón Atmosférica B-657 Canilla 5.
  • Página 8 All manuals and user guides at all-guides.com Noter: Si le dispositif être un L’Installation Typique: élément séparé, avec l’absence La Vanne-Caisse-Vide d’une ligne du Niveau de L’Installation Critique (CIL), le 1. La vanne-caisse-vide devoir être fond extrême de la coulée de N°.9 installer avec l’alimentation brancher devoir être utiliser pour déterminer au fond et la sortie brancher à...
  • Página 9 All manuals and user guides at all-guides.com L’Installation Typique: B-0968-RK01 B-0969-RK01 (Trousse) 0,96 cm (Trousse) 1,28 cm Suivre les instructions dans la section de la vanne-caisse-vide, de l’étape 1 jusqu’ à l’étape 5. Deux installations typiques des éléments de T&S aller avoir l’aspect comme indiqué...
  • Página 10 All manuals and user guides at all-guides.com Normale Installation: Anmerkung: Falls das Gerät eine separate Einheit ist, ist, falls eine Einfacher Vakuumschalter kritische Einbauebene fehlt (CIL), 1. Bei der Installation des nach der Installation der äußerste untere Rand des Gußstückens Nr.9 zur Vakuumschalters muß...
  • Página 11 All manuals and user guides at all-guides.com Normale Installation: B-0968-RK01 0,96 cm (Instandsetzungssatz) Die Anleitungen fur den einfachen oder B-0969-RK01 1,28 cm Vakuumschalter, Schritt 1 bis 5, (Instandsetzungssatz) befolgen. Die Installation von zwei typischen T&S Einheiten sieht wie folgt aus:...
  • Página 12 All manuals and user guides at all-guides.com RELATED T&S BRASS PRODUCT LINE B-0965 Atmospheric Vacuum Breaker Assembly with Exposed Outlet B-0929 Atmospheric Back Flow Preventer B-0456 Atmospheric Vacuum Breaker Assembly T&S BRASS AND BRONZE WORKS, INC. A firm commitment to application-engineered plumbing products 2 Saddleback Cove, P.O.

Este manual también es adecuado para:

B-0969