Installation Instructions – ClearCurve
5.
Hang the top housing onto the wedge plate and tighten
the two set screws to 20 in-lbs (Figure 5).
6.
Make conduit connections to the housing by using
outdoor rated sealed conduit connections. Fixture
option C1 has 1/2" NPT and C2 has 3/4" NPT. Make
the power connections in the top housing to the wire
plug assembly wires. See Figure 4A, 4B, or 4C for wire
connections.
7 .
Install the fixture door. Hang the door by the two ball
end cables by routing the cables through the brackets
(Figure 7). Make the wire harness plug connection from
the top housing to the door.
8.
Swing door to the closed position and tighten the eight
phillips flat head screws to 20 in-lbs. Use care not to
push on the lens to close the door.
Battery Option
Tools Required: None
1.
Before installing the fixture to the wall, connect the
plug together in the back of the fixture housing.This
will turn on the LEDs with battery power. Connect
the UnSwitched wire (black wire with white stripe) to
electrical power that will not be switched off. When
power is turned on the LEDs will turn off and begin the
battery charging process.
2.
Make wire connections per Figure 4B.
3.
Once fixture is installed and electrical power is
connected, then the test switch can be depressed to
simulate a loss of power (to the Unswitched power
lead). This will turn on the LEDs with battery power
while the button is depressed.
Pole Mount
Tools Required: #2 Phillips head screwdriver, socket wrench,
¾" socket, ¾" wrench, torque wrench.
1.
The fixture comes with a wall mount wedge plate
pre-installed. Remove the wall mount wedge plate and
discard. (Figure 1.)
2.
The pole mount arm is designed for a square or round
pole. Round pole installation will require the break-away
tabs to be removed. Use pliers to remove tabs.
(Figure 8.)
3.
Using provided 1/2" hardware, secure the pole mount
arm to pole. Torque bolts to 40 ft-lbs. (Figure 9.)
4.
Attach the quick-connect adapter to the fixture, pulling
the luminaire supply leads through the wedge plate
center hole. Tighten the (2) ¼-20 lock screws on the
fixture to 20 in-lbs. (Figure 10.)
4
Cooper Lighting Solutions
IB516118EN
Installation instructions
For Round Pole
Installations,
Break away Tabs
Figure 8.
Split Washer
Washer
1/2" Bolt
Washer
Figure 9.
A
Figure 10.
9/16" (14.3mm)
Diameter Hole and Slot
7/8"
4-7/8"
(22mm)
(124mm)
Max
1/2" Nut
Detail A