S
Key increases the values shown on the display R.
T
Key reduces the values shown on the display R. U-V- Power sockets for earth cable and spot-
welding gun.
U-V
Power sockets for earth cable and spot-welding gun.
W
3-pin socket to which to connect the male patch connector of the spot-welding gun, essential for manual
mode. Warning: use only original torches; others might damage the machine.
X
Switch that turns the machine on and off.
Y
Mains cable
7
EARTH CONNECTION
The earth cable must be fastened as close as possible to the point where you will be working.
To fasten the quick earth supplied with the cable, proceed as follows:
for manual mode LEd P lit.
1)
fasten the heating electrode to the welding gun
2)
Press the button H; the LEd G lights.
3)
use the key T to adjust the time to the minimum (05)
4)
Rest the earth as close as possible to the working area, after first removing all paint.
5)
Rest the gun near the earth and press the trigger.
6)
Raise the gun and turn the nut screwed onto the earth probe clockwise.
for automatic mode, LEd Q is lit.
1)
fasten any electrode to the welding gun
2)
Press the button H; the LEd G stops flashing.
3)
use the key T to adjust the time to the minimum (05)
4)
Rest the earth probe as close as possible to the working area, after first removing all paint.
5)
Rest the gun near the earth; wait for the machine to detect the contact and make the spot-weld
6)
Raise the gun and turn the nut screwed onto the earth probe clockwise.