Urmet Yokis MTV150EBRP Instrucciones De Instalación página 10

Control de atenuación conectado para control de luz 1 módulo
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
OPERATION
A short press on the button on the module allows you to turn the light on or off at 100%. A double press allows you to set the
lighting to the stored intensity value. The two functions can be reversed by performing 29 presses after unlocking the module.
Hold the button pressed (with the light on) to change brightness and store the setting. The brightness level reached is stored
when the button is released. Press again to reverse the dimming (up-down or down-up).
Press three times to set brightness to 50% and four times to set brightness to minimum level (adjustable).
Press six times for 100% brightness for 12 hours; press seven times to activate the children night light function.
This is outlined in the following table:
N. of presses
1
2
3
4
Minimum level
6
7
Child night light mode
DIRECT MODE RADIO CONNECTION
1. Step 1
Press the pushbutton to be connected on the transmitter 5 times (*).
The transmitter LED will start flashing for 30 seconds indicating that the system is waiting for connection.
(*) A brief press must be shorter than 0.8 seconds.
2. Step 2
While the transmitter LED is blinking, briefly press the "Connect" area of the receiver (located at the top of the case).
Warning: the receiver must be powered.
To delete a connection: repeat the procedure above.
CONFIGURATION
The MTV150EBRP timed dimmer also implements timer and child night light functions.
Important: Firstly, use a 23 press sequence to unlock the MTV150EBRP and configure it.
NOTE: To configure with remote control in direct mode, the button must be configured in bistable on/off mode (default).
Simply press 21 times to lock the module and prevent any changes to settings (replay: 1 flash).
WARNING: The MTV150EBRP will lock automatically after one hour.
All configurations are stored in the case of blackout.
1) 100% light: a brief press of the button increases brightness to 100% (factory setting).
2) Recall memory: the last brightness level stored by means of one long press can be recalled by pressing briefly twice (factory
setting).
3) 100% mode or brief press to recall memory: In some applications it is preferable to recall the memory the first time you
press it. Press 29 times to activate or deactivate the function. In this case, two presses are required to obtain 100% lighting.
The module is configured to 100% mode by default.
4) Timer configuration: The time can be configured from 2 seconds to 4 hours by means of short press sequences (see
table). Press 25 times to set the time in seconds (from 2 to 240 seconds) instead of minutes. Press 26 times to return the setting
to minutes. The timer is off (unlimited time) by default.
5) Switch-off warning: At the end of the set time, the module will flash briefly and extend lighting for another 60 seconds (or
10 seconds if the time is set in seconds). During this time, pressing the button again with restart the timer. The warning function
is preset by default. Press 24 times to deactivate (and reactivate) the function.
6) Relay mode: The MTV150EBRP works as a simple relay instead of a dimmer in this mode. Press 20 times to activate (or
deactivate) the mode (reply: 10 flashes). Dimmer is the default mode.
7) Children night light: 7 short presses activate the children night light mode. The light sets itself to 20% and lighting
progressively dims in the course of an hour to leave only a night courtesy light for 12 hours.
DS1054-076
Preset dimmer settings
100% mode
100%
Memory
50%
100% for 12h
Memory mode
Memory
100%
50%
Minimum level
100% for 12h
Child night light mode
P10
loading

Este manual también es adecuado para:

5454813