E5
Malfunction of outdoor unit
Testing fault of zero-crossing signal
E6
E7
EEPROM malfunction
Fault code table for inverter series
LED Display
Time light flash
Defrost,run, protection light flash
Deforst light flash
Protection light flash
Run, defrost light flash
Run, time light flash
Defrost, time light flash
Defrost warning lights flash
Timing warning lights flash
Running defrost timing lights flash
Defrost timing warning lights flash
Running timing warning lights flash
Running defrost timing
EF
Display
E2
Room temperature T1 sensor error
E3
Evaporator temperature T2 sensor error
E4
Evaporator outlet temperature T2B sensor error
EE
Water full filled error
E9
Indoor unit and wired controller communication error
Indoor unit and wired controller communication error
E7
E7
Indoor EEPROM error
E8
Indoor fan motor speed lose protection
F4
Outside ambient temperature T 4 sensor error
F5
Discharge temperature T5 sensor error
P9
Outdoor fan motor protection
E5
Outdoor unit error
FE
Outdoor EEPROM error
F6
Condenser temperature T3 sensor error
P5
Condenser temperature T3 too high protection
PA
Anti-typhoon protection
DC side over-voltage
L1
DC side over-current
PE
EF
Mode conflict
P6
Inverter IPM protection
H6
3 times P4 protection (Reserved)
H5
3 times P2 protection (Reserved)
E1
Communication error between indoor and outdoor unit
High pressure protection
P1
P2
Low pressure protection
P4
Outdoor discharge temperature too high protection
E0
Three phase sequence error
10
Model conflict
Error Description