Svans Kiel SV5 Instrucciones De Uso página 7

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
EN-
Connection to the power supply
The water heater is designed for 12 volts DC only.
Voltage range: 10-14.6 volts Current connection: 100Watt/8A // 200W/16A
The fuse protection of the water heater - variant: 100Watt - 10A // 200Watt – 20A
Before connecting to the power supply network, be sure to fill the water tank with water !
°
Cold; boiler is switched off
Automatic frost protection active; the unit
*
switches on when the water temperature
drops below 7°C.
The water temperature is around +/- 35°C
I
E
Energy saving mode +/- 65°C setting the best
ratio between energy consumption and hot water
III
The water temperature is +/- 80°C
E = Energy saving mode 65°C - To prevent the growth of bacteria in the water, it is
recommended to set the water temperature to at least 60°C. This also reduces the risk of
damage to the device. This also reduces the risk of damage to the device.
Frost protection
If the unit is left unused in a room where the temperature drops below 0°C, the following three
1. To prevent freezing, start the water heater and turn the control knob to the frost position.
The water temperature is automatically kept at 7°C. The current consumption is then: -
0,5A/hour. It is suitable for the duration of 1-10 days.
2. Take off both water hoses, put one hose on the inlet side (blue) and suck once.
The tank runs empty (suction effect) Make sure that the water hose is long enough.
Make sure that the water hose is long enough, preferably when the hose is out of the vehicle,
-must be deeper than the tank. (Suction effect).
3. Remove the hot water tank. To do this, disconnect the two water connections and power
cables Unscrew the boiler, turn the water tank upside down (180 degrees) until the
water hasdrained out until the water has drained out.
yield
options should be selected;
7
loading