7.3 ChIP / kEy PROGRaMMING PROCEDURE (ExaMPLE: SEttING thE DatE)
Plug in the chip or key. Pressing the "ENTER" button calls up the working display. Pressing
the "ENTER" button again takes you to programming mode.
All the parameters can be entered using exactly the same procedure and sequence as
described for setting the parameters in manual mode (see section 6.2). A date can be ente-
red in the format 'DD-MM-YYYY', so that you can determine the useful life of the battery.
DATE
01-01-2000
EXIT & SAVE
it using the '+' or '-' button. Press the "ENTER" button again, and the 'month' number flashes.
It can now be changed in the same way using the '+ / -' buttons. Use the same procedure
to set the current year. Press the 'ENTER' button once more to complete the procedure.
Confirm the "EXIT & SAVE" menu point by pressing '+' or '-', and the new values are per-
manently stored in the BID chip.
If you do not wish the data to be accepted, you must press the "ENTER" button. In this case
you will be returned to the working display for the programming procedure.
7.4
REaDING OUt thE Data ON a BID ChIP / kEy
When you connect a BID chip or key , you must then press the "VIEW" button. In addition to
the normal displays, as described in section 8.2 "VIEW", the following data can be read out
in order to obtain an up-to-date overview of the exact state of the battery.
The various display levels are shown by pressing the '+' / '-' button.
CAP CH.
CAP DC.
MAX. CH.
MAX. DC.
CH.COMPL
PEAK
Operating Instructions
All manuals and user guides at all-guides.com
Power Peak ® B7 EQ-BID
Press "ENTER" to confirm the "DATE" menu point,
and the date entry process starts. On the left of the
top line the 'day' number flashes: you can now change
The last charged-in or discharged capacity for the
1250mAh
charge or discharge process is displayed.
0850mAh
The maximum capacity value for all
1450mAh
charge / discharge processes is displayed.
1200mAh
0015CYC
The screen displays the number of charge cycles and
the peak voltage.
9.10V
16