KNOW YOUR GENERATOR
See Figure 1.
The safe use of this product requires an understanding
of the information on the product and in this operator's
manual as well as a knowledge of the project you are
attempting. Before use of this product, familiarize your-
self with all operating features and safety rules.
AC CIRCUIT BREAKERS
The circuit breakers are provided to protect the genera-
tor against electrical overload. The circuit breaker may
be reset by pressing the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust
drawn into the unit during operation.
DIGITAL DISPLAY
The digital display shows AC voltage output, frequency,
how long the engine has been running during the
current usage period, and the total number of hours
the unit has been used.
ENGINE SWITCH
The engine switch is used alone or in combination with
the recoil starter grip to start the engine. It is also used
to turn the engine off.
FUEL VALVE
Fuel flow from the fuel tank to the engine is turned on
and off using the fuel valve.
GROUND TERMINAL
The ground terminal is used to assist in properly groun-
ding the generator to help protect against electrical
shock. Consult with a qualified local electrician for
grounding requirements in your area.
www.ducsonpower.com
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level
of lubricant in the crankcase is insufficient.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
OIL DRAIN PLUG
When changing the engine lubricant, unscrew and
remove the oil drain plug to allow old engine lubricant
to be drained.
RECEPTACLES
These can be used for operating appropriate applian-
ces, electrical lighting, tools, and motor loads.
RECOIL STARTER GRIP
The recoil starter grip is used (along with the engine
switch) to start the generator's engine.
EFI
Electronic fuel injection (EFI), an onboard electronic
engine management system that can greatly reduce
CO emissions generated by the portable generator's
engine. By significantly reducing the amount of CO a
portable generator emits, the likelihood of CO poiso-
ning and death is greatly reduced.
CO SENSOR
The CO Sensor is able to detect the carbon monoxide.
If the CO concentration in a certain range, the CO
Sensor will immediately "bleep" and the light will blink;
If the concentration in a high range, the CO Sensor will
shut the generator off.