Taurus HERMITAGE 90 GLASS Manual Del Usuario página 12

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Service:
Make sure that the appliance is serviced only by
specialist personnel, and that only original spare
parts or accessories are used to replace existing
parts/accessories.
Any misuse or failure to follow the instructions for
use renders the guarantee and the
manufacturer's liability null and void.
Description
A Switches
B One way valve
C Aluminium filter
D Lights
E Body
F Chimney
Installation
Be sure to remove all packaging material from
inside the appliance.
Make sure the air vented is not sent through the
ducts used to vent fumes from other gas or fuel
appliances.
Specific air venting regulations applicable must
be complied with when installing the appliance.
Respect the legal provisions concerning safety
distances from other elements such as pipes,
electrical connections, etc.
The minimum distance between the support
surface of the cooking elements and the lower
part of the appliance is 65-75cm. (This distance
can be greater if specified in the cooking
elements' installation instructions).
Do not cover or obstruct any of the openings of
the appliance.
The plug must be easily accessible so it can be
disconnected in an emergency.
Do not add new sections to the extraction tube
provided, as it could cause the appliance to
malfunction.
Make sure you have the necessary elements for
the installation before you start:
Impact drill
8 mm drill bit
Philips screwdriver
Elements contained in the box for installation
(Fig.1):
1. 4X30 mm screws (9 pcs.)
2. 3X10 mm screws (2 pcs.)
3. Screw plug (9 pcs.)
4. Wall bracket
5. Chimney hangers (2 pcs.) (small and large)
6. Lower chimney
7. Upper chimney
8. One-way valves (2 pcs.)
9. Exhaust pipe
Assemblage
If you have an outlet to the outside, your hood
can be connected as shown in the image below
by means of an exhaust pipe (with an internal
diameter of 150 mm).
NOTE: Before installation, turn the unit off and
unplug it from the power outlet.
Before installation, you must remove the grease
filters as shown below, you must press the lock
and pull down:
Installation for exterior ventilation:
1. Place the wall bracket on the wall and mark
the 3 points where the screws should be fixed.
(As a reference, take the measurements of
Fig.2).
2. Drill 3 holes of 8 mm and insert 3 screw plugs
there.
3. Replace the wall bracket and fix it to the wall
with the 4X30 mm screws.
4. Hang the body of the extractor hood and with
the filters removed you will see two more fixing
points. You must mark these two points, remove
it and repeat what has been done previously
(drill and place studs). We hang again the
extractor hood and fix two more 4X30 mm
screws.