Velleman HQ Power HQSM10006 Manual Del Usuario página 7

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
6.
Installation
Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
The carrying construction must be able to support 10 times the weight of the device for 1 hour
without deforming.
The installation must always be secured with a secondary attachment e.g. a safety cable.
Never stand directly below the device when it is being mounted, removed or serviced. Have a
qualified technician check the device once a year and once before you bring it into service.
Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
Install the device in a location where you can easily access the power cord.
Install the device in a well-ventilated area.
Overhead mounting requires extensive experience: calculating workload limits, determining the
installation material to be used... Have the material and the device itself checked regularly. Do not
attempt to install the device yourself if you lack these qualifications as improper installation may
result in injuries.
For truss mounting, use an appropriate clamp (not incl.) and fit an M10 bolt through the centre of the
(folded) bracket.
Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.
Make sure there is no flammable material within a 0.5 m radius of the device.
Have a qualified electrician carry out the electric connection.
Connect the device to the mains with the power plug. All devices must be powered directly off a
grounded switched circuit. Do not connect to a dimmer pack.
The device has a power output to supply power to another device. When connecting several devices
in a daisy chain via this output, make sure that the total current does not exceed the power line's
nominal current. Use power cables with an adequate section.
The installation has to be approved by an expert before the device is taken into service.
7.
Operation
7.1
Preparing Your Smoke Machine
1.
Make sure the smoke machine is switched off.
2.
Open the tank compartment, remove the fluid tank from its compartment and remove the cap.
3.
Verify that the plastic hoses attached to the cap are in place and in good condition.
4.
Pour smoke fluid into the tank and close the tank.
5.
Replace the tank into its compartment and close the compartment. Make sure the plastic hose
entering the smoke machine from the fluid tank is not bent or kinked.
6.
If you have not done so, connect the smoke machine to the mains, switch it on and let it warm up.
The smoke machine is ready-to-use after approximately 7 minutes.
In any operation mode, the display must read READY TO FOG to output
7.2
Using your Smoke Machine
Control Panel Description
FUNCTION
enter the programming mode
VOLUME
output volume control
TIMER
start timer operation
MANUAL
manual smoke output
UP
upwards through the menu list
DOWN
downwards through the menu list
Menu
Refer to the illustration on page 3 of this manual.
V. 02 – 10/08/2017
HQSM10006
smoke.
7
©Velleman nv
loading