Technical Data
Maximum Height / Manometric Total
Maximum Height Value
Allows particle passage up to
Approximate Flat Immersion Height
Minimum Water Level for Operation
Input Interruption Height
Output Automatic Interruption Height
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
WARNING
Before gaining access to the terminals all power sources should be disconnected.
Power Requirements
WARNING
To prevent electric shock, the tool shall be grounded while in use.
• Connect the plug into a correctly grounded outlet as shown in example A. Not all the
outlets are properly grounded. If in doubt, verify with a qualified electrician.
• If the outlet where you will connect the tool has two poles (2 orifices), UNDER ANY
CIRCUMSTANCE, DO NOT REMOVE OR ALTER THE PLUG'S GROUND CONNECTOR.
Use a temporary adaptor as shown in example B and always connect the ground
conductor lug as shown.
When using an extension cable, verify the gauge is enough for the
CAUTION
power that the tool needs. A lower gauge cable will cause voltage drop in the line,
resulting in power loss and the motor will overheat. The following table shows the right
size to use depending on cable's length and the ampere capability shown in the tool's
nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
WARNING
All the wiring, electric connections and the ground connection in the system shall comply with the OFFICIAL
MEXICAN STANDARD NOM - 001 - SEDE, ELECTRIC INSTALLATION (USE) or with the local codes and ordinances. Call
a certified electrician. It is advisable that the pump is fed with a circuit that includes a differential switch with an assigned current
no higher than 30 mA
WARNING
When operating power tools outdoors, use a grounded extension cable
labeled "Outdoor Use"
and reduce the risk of electric shock.
Code
Description
Voltage
Power
Flow
Maximum Depth
Power Cable
Conductors
Insulation
Thermal insulation on motor winding: Class F
Number of
Conductors
3 (one grounded)
brand. These extensions are special for outdoors use
BOS-1SM
12607
Heavy Duty Submersible Pump
120 V
1 Hp (750 W)
57 gal/min
23 ft
26 ft
33 ft
1 3/8"
3/16"
3"
21"
4"
118 AWG x 3 C with 221 °F Insulation Temperature
Class I
Power Cord Grips t: Type "Y".
Tool Build Quality: Basic insulation
Authorized Service Center.
Extension Gauge
From 6 ft to 49 ft
|
18 AWG
16 AWG
14 AWG
8 AWG
BOS-1-1/2SM
12608
1 1/2 Hp (1 100 W)
74.7 gal/min
33 ft
5"
IP Grade
IPX8
A
B
CAUTION
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3