PARAMETER
Code
Name
I.101 Dig output 2 cfg
Digital output 2 configuration
I.102 Dig output 3 cfg
Digital output 3 configuration
I.103 Reserved
I.150 Exp DigOut 1 cfg
Extended digital output 1 configuration
I.151 Exp DigOut 2 cfg
Extended digital output 2 configuration
I.152 Exp DigOut 3 cfg
Extended digital output 3 configuration
Setting of the Analog Input 1 type referen-
I.200 An in 1 Type
ce (voltage)
I.201 An in 1 offset
Analog Input 1 offset
AGL50-EV
DESCRIPTION
[25] Encoder run
[26] Extern fault
[27] No ext fault
[28] Serial TO
[29] freq=thr1
[30] freq!=thr1
[31] freq>thr1
[32] freq<thr1
[33] freq=thr2
[34] freq!=thr2
[35] freq>thr2
[36] freq<thr2
[37] HS temp=thr
[38] HS temp!=thr
[39] HS temp>thr
[40] HS temp<thr
[41] Output freq
[42] Out freq x 2
[43] CoastThrough
[44] EmgStop
[45] DC braking
[46] Drv OL status
[47] Drv OL warn
[48] Mot OL status
[49] Reserved
[50] Reserved
[51] Contactor
[52] Contactor UP
[53] Contactor DW
[54] Brake cont
[55] Lift start
[56...77] Reserved
[78] Timer 1 out
(fw 03.07)
As for I.100
As for I.100
As for I.100
As for I.100
As for I.100
[0] +/- 10V
[1] 0-10V/0-20mA
PICK LIST
Selection
Description
Active when the RUN
contactor has to be
closed, either for upward
or downward motion
Active when the RUN
contactor has to be clo-
sed for upward motion
Active when the RUN
contactor has to be
closed for downward
motion
Active when the mecha-
nical brake has to be
released
Active when the inverter
output bridge is enabled
and DC brake is not in
progress
Output of Timer 1
Bipolar ± 10V
Unipolar +10V
Def.
Min
Max
Unit
54
0
78
2
0
78
52
0
78
53
0
78
0
0
78
1
0
1
0
-99.9
99.9
%
Variat.
IPA
113
114
116
117
180
118
0.1
119
49