Cherubini BLUE BUS TDS Serie Instrucciones página 38

Ocultar thumbs Ver también para BLUE BUS TDS Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

RAIN SENSOR (BLUE BUS TDS - BLUE BUS TDS RX)
Sensor element
RAIN SENSOR - Ref. A520017
SPECIAL FUNCTIONS (BLUE BUS TDS RX)
SHORT-TERM SETTING OF A REMOTE CONTROL
This function makes it possible to store a remote control temporarily, for example, with the purpose of
setting the limit switches during assembly in the factory. A later final saving of the remote control will
be possible using the appropriate command sequence (see: "SETTING THE FIRST REMOTE CONTROL").
The operations described below can be carried out only when the control unit has just come out of the
factory or after a full memory clearing (see: "FULL MEMORY CLEARING"). The control unit makes the
following operations possible only within the time limits described in order to make sure that the short-
term setting is used only in the installation or factory setting phase and not during daily use, the control
unit enables the following operations only within the time limits described below.
Power up the control unit, make sure that no other control units having an empty memory are powered
up in the same operating range.
Within 30 seconds after start, press the B and C buttons simultaneously until the motor gives a
confirmation signal.
The remote control will remain stored for 5 minutes, while the control unit is powered up. After 5
minutes or when the control unit has its power cut off, the remote control will be cancelled.
T1: First remote control to be set
B
+ C
T1