It is possible to run the motor through a switch connected with three wires (up, down
and common).
The switch must be equipped with mechanical or electrical interlock, to prevent
two commands being sent simultaneously. Furthermore, the switch must be an
unstable pushbutton: releasing it, the switch opens.
L
N
PE
E P
MOTOR
The motor automatically recognizes the switch-type (with 1 or 2 buttons) and
sets the proper operational mode.
COMMAND MANAGEMENT FROM WHITE WIRE
UP-STOP-DOWN-STOP / UP-DOWN / UP-DOWN "DEAD MAN"
NB: The default function provided in the motors leaving the factory is: UP-STOP-DOWN-
STOP for singular UP/DOWN button switch. (Not for the switch with two independent
UP-DOWN buttons!)
+
B
C
The possible settings are 3 and are available in the following order:
- UP-STOP-DOWN-STOP (factory setting)
- UP-DOWN (for 2 independent buttons)
- UP-DOWN "DEAD MAN" (for 2 independent buttons)
To switch from one setting to the following, perform the sequence as many times as
necessary to reach the desired setting.
2-BUTTON SWITCH
1 - NEUTRAL
2 - PHASE
3 - WIRED SWITCH (WHITE)
1
2 3
PE - EARTH
B
36
C
2 sec