"DOWN/ROOM LIGHT" key: in programming mode or when setting room temperature it is
used to reduce the value displayed; otherwise it is used to switch on/off the cold room light.
"SV.M./UP" key: in programming mode it is used to increase the values displayed. If pressed
for more than 5 seconds it enables manual defrost to be carried out.
"ON/OFF" key: when pressed for 3 seconds it turns the unit on or off.
"Enter" key: it gives access to programming menu and submenus. Access to the
programming mode requires the installator's assistance and should be effected only if
necessary.
9
Checks, regulations and adjustments
Before turning the unit on, check that:
- locking screws are tight
- electrical connections have been carried out correctly.
In the event that the unit has been opened:
- no tools were left inside
- assembly is correct
- there are no gas leaks
- front cover is secured correctly
9.1
Starting
Before starting the unit act as follows:
Connect the unit to the mains. The display is turned on and shows OFF.
-
If the unit has a preheating cycle, leave it in this condition for at least 3 hours.
-
If the unit has a voltage monitor, leave it in this condition for at least 7 minutes to have the
-
counting phase carried out.
Press ON/OFF key to switch the unit on.
-
Set the required cold room temperature.
-
ATTENTION
Medium temperature range :
Low temperature range :
Setting room temperature:
•
Connect the unit to the mains. OFF is displayed.
•
Press ON/OFF key, for 3 seconds, to switch the unit on.
•
Press SET key. The wellow led lights up and the previously set temperature is displayed.
•
To change this value press following keys:
Press SET key to confirm the set value or wait 15 seconds, Now the unit is operating and does not require any
further programming. The refrigerating cycle is fully automatic according to the factory-set parameters, which can
be modified by authorised personnel only.
•
•
UP to increase temperature
•
DOWN to decrease temperature
+5 / -5°C
-18 / -25°C