1.10 Operation
Is the device set and programmed correctly (function;
for counters, max. counting frequency)?
1.11 Failure possibilities and causes
Impossible to use the keys:
• Key lock input activated
Counter does not count:
• Wrong or reversed wiring of the counting input
• Setting of an input signal not matching the pulse gen-
erator
• Polarity (NPN/PNP) reversed
• No ground connection between the pulse generator
and the counter
Overview
Model
Operating mode
6.130.012.8x0
Count
6.130.012.8x2
6.130.012.8x3
6.131.012.8x0
Cnt.Dir/Up.Dn
6.131.012.8x1
6.131.012.8x3
Up.Dn
6.132.012.8x3
Cnt.Dir
6.133.012.8x0
Quad/Quad2
6.133.012.8x1
Table 1
DC input modes:
Fast and slow counting inputs
Count:
INP A:
Fast counting input
INP B:
Slow counting input
Counting and counting direction input
Cnt.Dir:
INP A:
Counting input
INP B:
Counting direction input
Differential counting input
Up.Dn:
INP A:
Adding counting input
INP B:
Subtracting counting input
Phase discriminator input
Quad:
INP A:
0° counting input
INP B:
90° counting input
Phase discriminator input with
Quad2:
pulse doubling
INP A:
0° counting input
INP B:
90° counting input
Each edge of INP A is counted.
• Maximum counting frequency exceeded
• Signal levels do not reach the switching threshold of
the counter
If, despite all, your device still does not operate, contact
your local representative or call us directly for technical
support.
When sending your device back, please attach a short
description of the failure, of the programming and of the
connection diagram, in order to allow us to reproduce
a possibly existing defect and to repair your device as
quickly as possible.
Counting inputs
INP A
0...0,7 V DC
NPN
4...30 V DC
PNP
10...260 V AC/DC
AC/DC
0...0,7 V DC
NPN
4...30 V DC
PNP
10...260 V AC/DC
AC/DC
10...260 V AC/DC
AC/DC
NPN
0...0,7 V DC
NPN
4...30 V DC
Options:
AC input modes:
Count:
Cnt.Dir:
Up.Dn:
INP B
7 kHz
0...0,7 V DC
12 kHz
0...0,7 V DC
30 Hz
10...260 V AC/DC
7 kHz
0...0,7 V DC
12 kHz
4...30 V DC
30 Hz
10...260 V AC/DC
30 Hz
10...260 V AC/DC
3 kHz
0...0,7 V DC
6 kHz
4...30 V DC
x = 5: no backlight
x = 6: with backlight
Counting and reset inputs
INP A:
AC/DC counting input
INP B:
AC/DC reset input
Counting and counting direction input
INP A:
AC/DC counting direction input
INP B:
AC/DC counting input
Differential counting input
INP A:
AC/DC subtracting counting input
INP B:
AC/DC adding counting input
NPN
30 Hz
PNP
AC/DC
–
NPN
7 kHz
PNP
12 kHz
AC/DC
30 Hz
AC/DC
30 Hz
NPN
3 kHz
NPN
6 kHz
Page 3 | ENG