Analogmodul AS-i IP20
Montageanweisung // Installation Instructions // ...
7
Parameterbits // Parameterbits // Bits de paramètres // Bit parametri // Bits
de parámetros
BWU1364, BWU1365
Bit P0:
1: 50 Hz filter in A/D converter active
0: 60 Hz filter in A/D converter active
Bit P1, P2
a peripheral fault can be released through channel:
P2
P1
0
0
1
0
0
1
Bit P3
1: peripheral fault is indicated
0: peripheral fault is not indicated
Subject to technical modifications; no responsibility is accepted for the accuracy of this information
Internet: www.bihl-wiedemann.de • Flosswoerthstr. 41 • D-68199 Mannheim
4
3
2
no
no
no
no
no
yes
no
yes
yes
1
yes
yes
yes
© Bihl+Wiedemann GmbH
phone: +49 621 33 996-0 • fax: +49 621 33 922 399