• The load must be kept within the rating stated on
generator rating plate. Overloading the generator will
damage the unit or shorten its life.
• The generator must not be run at excessive speeds.
Operation at excessive speeds will increase the
hazards of personal injury.
• Do not modify parts which may increase or decrease
the governed speed.
• Only use extension cords that are grounded and are a
sufficient wire gauge for the application. When using an
extended wire or a mobile electric net, if the wire
2
diameter is 1.5 mm
, it cannot exceed the length of 60
m. If the wire diameter is 2.5 mm
length of 100 m.
• The exhaust system can become hot enough to ignite
flammable materials. Do not operate the engine near
flammable materials. Do not use the generator in damp
conditions.
• Do not store fuel indoors or try to refuel a generator
while it is running.
• Do not cover unit while it is being used.
• To prevent poisoning or fire when operating, never use
the generator in close proximity to flammable materials.
• The unit must reach the operating speed before the
electrical loads are connected. Disconnect the load
before turning off the generator. Turn off all of the
equipment powered by the generator before shutting
down the generator. The unit should not be connected
to other power supply outlets.
• Protection against electrical shock is dependent on the
circuit breakers specially matched to the generating
set. If the circuit breaker requires replacement contact
a local retailer for replacement with a circuit breaker
having identical rating and performance characteristics.
• Ensure that the generator does not have any damaged
hoses, loose or missing clamps, damaged tank or cap
before use. All defects should be corrected before use.
• The installation and major repair of the generator can
only be conducted by specially trained people. Before
transporting the generator, drain all fuel to prevent
leakage.
• Store the generator in a well-ventilated area with the
fuel tank empty.
COMPONENTS (Fig. 1)
CONTROL PANEL (Fig. 2 & Fig. 3)
*Keep a record of the engine and frame serial numbers
and the date of purchase for your future reference. Refer
to these serial numbers when ordering parts and when
making technical or warranty inquiries.
Date of purchase:
Engine serial number:
Frame serial number:
CONTROLS
Engine Switch (Fig. 4)
Starts and stops the engine.
8
2
, it cannot exceed the
Key position:
O (OFF): Stops the engine. Key can be removed or
inserted.
I (ON): Runs the engine after starting.
S (START): Starts the engine by operating the starter
motor.
*EG2250A and EG2850A equipped with I (ON)/O (OFF)
switch only
Starter Grip (Fig. 5)
To start the engine, pull the starter grip slowly until
resistance is felt and then pull swiftly.
NOTICE:
Return the starter grip back gently to prevent damage to
the starter. Do not allow it to snap back against the
engine.
If the generator is not equipped with a 12-volt battery to
operate the starter motor or if the battery does not contain
enough charge to operate the starter motor, the recoil
starter is used to start the engine.
Fuel Valve Lever (Fig. 6)
The fuel valve is located between the fuel tank and
carburetor. Fuel is allowed to flow from the fuel tank to the
carburetor when the valve lever is in the "I (ON)" position.
Return the fuel valve lever to the "O (OFF)" position after
stopping the engine.
Choke Rod (Fig. 7)
The choke is used to provide an enriched fuel mixture
when starting a cold engine. Operate the choke rod
manually to open and close the choke. Pull the rod out
toward "CLOSED" to enrich the mixture for cold starting.
Ground Terminal (Fig. 8)
The generator ground terminal is connected to the
generator frame, the generator's metal non-current-
carrying parts, and each receptacle's the ground
terminals.
Before using the ground terminal, consult a qualified
electrician, an electrical inspector, or a local agency
having jurisdiction for local codes or ordinances that apply
to the intended use of the generator.
DC Terminals
The DC terminals are used only for charging 12-volt
automotive type batteries.
The terminals are colored red and black to identify the
positive (+) and negative (-) terminals, respectively. Make
sure to connect the battery to the generator DC terminals
with the correct polarity (battery positive to the generator
red terminal and battery negative to the generator black
terminal).
DC Circuit Protector (Fig. 9)
When the DC charging circuit is overloaded, there is a
problem with the battery, or the connections between the
battery and the generator are incorrect, the DC circuit
protector automatically shuts off the DC battery charging
circuit.