Decommissioning; Troubleshooting - Schneider Airsystems MAS 575-15-60 D Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

GB
MAS
2.6.12 Check screw fittings
1. Check all screw connections for tight fit
and retighten if necessary.
2. Observe the tightening torques (tighten-
ing torques calculated according to VDI
2230).
2.6.13 Replacing the safety valve
1. Detach the safety valve (item 11) by un-
screwing it anticlockwise.
2. Screw the new safety valve into place by
screwing it clockwise.
2.6.14 Cleaning the dirt arrester
1. Place collection tank under the dirt ar-
rester.
2. Remove locking screw by turning in an
anticlockwise direction (Figure 13a).
3. Remove screen and clean with water
(Figure 13b).
4. If the screen is defective or can not be
cleaned, replace.
5. To install, follow steps indicated for re-
moval in reverse order.
2.7

Decommissioning

Observe the safety instructions!
2.8

Troubleshooting

Observe the safety instructions!
Problem
A
Protective
motor
switch
interrupts
power supply.
B
Pressure relief does
not function
II/18
Cause
In case of malfunctions (e.g.
overheating;
low
extension cable too long or
with incorrect cross-section),
the protective motor switch is
tripped.
The pressure relief is shut
down by an interruption of the
power supply or voltage drop
in the mains when the com-
pressor is switched on.
2.7.1 Preservation
Preservation of oil-lubricated compressors is
necessary if the compressor is taken out of
service for a long period (over 6 months) or
is new from the factory and will not be oper-
ated until much later.
1. Switch off the compressor. Disconnect
the power supply.
2. Allow the oil to drain. See Chap. 2.6.6.
3. Fill corrosion inhibiting oil (viscosity SAE
30). Insert the oil filler plug or oil dip-
stick.
4. Allow the compressor to warm up, switch
it off.
5. Refit intake filter, seal watertight with
Scotch tape.
6. Switch off the compressor. Disconnect
the power supply.
7. Drain condensate.
8. Depressurise the compressor.
Store the compressor dry and do not subject
it to large temperature fluctuations.
2.7.2 Disposal
Dispose of the unit and packaging materials
according to applicable regulations.
Remedy
X
Switch off the compressor. Wait a
voltage;
short while. For compressors
with an external protective motor
switch:
Switch on the compressor.
If the protective motor switch is
triggered again: switch off the
compressor. Disconnect the pow-
er supply. Contact the service
partner.
X
Switch off the compressor. It de-
pressurises. Switch on the com-
pressor.
actuate
the
switch.
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

A 888 009A 888 016A 888 021

Tabla de contenido