Defrost Timer; Maintenance (To Be Carried Out By Qualified Service Personnel Only) - Bras FBM Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2
Monthly on FBM 1P, FBM 2 and FBM 3 models: remove
the dust from the condenser filter. A blocked filter will reduce
performance and could cause compressor failure.
Remove the only left panel (from faucet side) unscrewing the
two plastic coated screws (see figure 16).
ATTENTION
Condenser fins are very sharp. Use extreme caution
when cleaning.
3
Replacement of lighted top cover bulb: remove the fixing
screw placed in the upper part of the top cover, remove the
lower part and replace the bulb (using a 24-28V 21W max
bulb). Reassemble the top cover and replace the fixing
screw.(see figure 17)
6. 1 MAINTENANCE (TO BE CARRIED
OUT BY QUALIFIED SERVICE
PERSONNEL ONLY)
1
Annually: remove the panels and clean the inside of the
machine including the base, side panels, condenser, etc.
2
Annually: Check if the auger bushings are worn out or
ovalized. If they are, replace them with new ones.
3
Never remove the insulating jacket from around the suction
tubing of the evaporator (the copper tubing located on the right
side of gear motor). In case the insulating jacket is missing
replace the entire parts with original spare parts from the
supplier.
4
In order to prevent any damages to the dispenser, all
plastics parts must be lubricated only with grease supplied by
the manufacturer or with another lubricating product suitable for
polycarbonate.
figure 16
figure 17

7 DEFROST TIMER

The Defrost Timer, located on the right side of the unit,
automatically switches the dispenser from Granita mode to Soft
Drink mode and the opposite. This means that during defrost
periods frozen Granita will melt to thermostat setting
temperature and once defrost period has expired, the product
automatically freezes down again to Granita setting viscosity.
To operate the defrost timer proceed as follows (see figure 18).
1
Set the time of the day by rotating the dial clockwise (arrow
A). Never rotate the timer counterclockwise as this would
damage the internal mechanism. Align the current time of day
with the arrow B on the timer face. This is a 24 hour timer
showing both A.M. and P.M.
2
Program the defrost timer by pushing out on the tabs C that
correspond to the hours desired to defrost. Each tab represents
15 minutes. A minimum of four to eight hours are required to
defrost frozen beverage (depending on ambient conditions).
Note: when all the tabs are pushed in the defrost function is OFF
(the machine operates as if it were not equipped with Defrost
Timer).
9
figure 18
Tabla de contenido
loading

Este manual también es adecuado para:

Fbm1pFbm2Fbm3

Tabla de contenido