Symmons Identity SLS-6710-1.0 Manual De Operaciones Y Mantenimiento página 4

Idiomas disponibles

Idiomas disponibles

Installation
9) With stopper in closed location,
insert pivot rod (T) into clevis strap
(W). Secure with spring clip (V).
V
T
V
10) To adjust stopper, select anoth-
er hole in clevis strap or loosen
thumb screw to slightly raise or
lower lift rod.
11) Attach drain body to drain trap.
12) Attach supply lines (M) to shut-off
valves and hand tighten. Using a
wrench, finish with one-half turn.
DO NOT overtighten.
Maintenance
1) Turn off water supply. Remove plug
button (B). Loosen and remove the
handle set screw (C), handle (A),
collar (D) and nut (E).
3
A
B
D
4
E
Troubleshooting Chart
Problem
Finish is spotting.
Symmons Industries, Inc.
Copyright © 2023 Symmons Industries, Inc.
1
W
13) Remove flow restrictor (J) and
flush supply lines free of debris.
Check for leaks.
2) Remove cartridge (H) and inspect
for debris. Replace cartridge if
necessary.
C
5
Elements in water supply may cause
water staining on finish.
31 Brooks Drive
M
1
2
J
H
Cause
Braintree, MA 02184
Phone: (800) 796-6667
symmons.com
14) Optional: Adjust limit stop wash-
er to limit handle turn to the hot
position if desirable.
2
1
Note: Counterclockwise to lower
temperature, clockwise to increase
temperature.
3) Install cartridge following steps
1 & 2 in reverse.
Solution
Clean finished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
Fax: (800) 961-9621
ZV-3204 REV F
042823
3
loading

Este manual también es adecuado para:

Identity sls-6712-1.0