Technical Installation Instructions and User Guide
Safety assembly
The.unit.must.be.installed.with.a.safety.assembly.that.meets.current.national.and.EU.standards,.connected.to.the.cold.water.inlet.tube.and.
suitable.for.the.maximum.working.pressure.indicated.on.the.technical.label.
It.is.advisable.to.use.a.safety.assembly.with.a.membrane.
The.safety.assembly.M-3/4.must.be.installed.as.close.as.possible.to.the.cold.water.inlet.and.the.water.flow.must.not.be.obstructed.by.other.
accessories.
If,.for.technical.reasons,.the.safety.assembly.cannot.be.installed.with.a.direct.link.to.the.cold.water.inlet,.a.rigid.link.with.the.same.dimensions.
as.the.M-3/4.cold.water.inlet.must.be.used.
GB
In.any.case,.the.link.must.be.made.using.a.material.that.is.able.to.withstand.the.temperatures.and.pressures.indicated.on.the.technical.label.
The.outlet.for.the.safety.assembly.should.never.be.obstructed.and.should.be.linked.to.vertical.evacuation.tubes.with.a.diameter.at.least.as.
large.as.that.of.the.unit's.connections.
It.is.recommended.that.the.safety.assembly.be.installed.as.low.down.as.possible.so.that.the.unit.can.be.drained.sufficiently.
If.the.supply.pressure.is.greater.than.4,5.bar,.a.pressure.reducer.must.be.installed.upstream.of.the.safety.assembly.
It.is.recommended.that.a.stop.valve.be.positioned.upstream.of.the.safety.assembly.
Always use new connection piping to make connections to a water supply network, never install used pipes. These pipes must also conform to the EN
61770 standard.
Water connection and preliminary operations
-.Verify.that.the.useful.thermal.power.from.the.generator.exceeds.the.power.that.the.tank.can.absorb.by.more.than.15%.
-.Verify.that.the.volumes.and.the.pre-charge.pressure.of.the.secondary.circuit.expansion.reservoir.are.suitable.for.the.system.
-.If.the.water.in.the.circuit.is.excessively.hard.(TH.>.5°F),.install.(upstream.of.the.tank),.a.correctly.adjusted.water.softener.
-.If.impurities.are.found.in.the.water.in.the.circuit,.install.a.suitable.filter,.making.sure.that.the.circulators.have.sufficient.flow.and.that.they
rotate.regularly.
-.Verify.that.the.thermostat.sensor.is.correctly.positioned.
-.Verify.that.the.thermostat.controls.are.functioning.correctly,.if.using.an.optional.electrics.kit.
-.Install.a.safety.assembly.that.meets.current.national.and.EU.standards,.and.which.is.suitable.for.the.maximum.working.pressure
indicated.on.the.product.identification.label.