1. Installation

Request assistance from an authorised
technician for installation, ordinary and
extraordinary maintenance and for putting
15 cm min
the device out of service.
The CO detector should be installed at
least 15 cm from the ceiling of every room
where there is a device that burns fuel.
Alternatively, it can be installed in places
where there is a long-term presence of
people particularly in the bedroom; in
this case it should be placed in the area
where occupants breathe.
The CO detector should not be installed
in:
• outdoors
• near stoves or cooking appliances
Fig. 1
• near sinks or taps
ENGLISH - 3