Condensate drain valve
10
Pressure switch with ON/OFF switch
11
Safety valve
12
Pressure gauge (vessel pressure)
13
Pressure gauge (working pressure)
14
Electric motor
18
Pressure reducer
19
Quick-action coupling
1.6
Commissioning
1.6.1 Before first use
Replace the sealing plug with the oil dip-
stick (item 03) and fill with compressor
oil. For oil quantity, see "Technical data"
chapter.
I/4
1.7
Compressor inspections
Special inspections are not required for this
compressor.
We recommend that a "qualified person" per-
form a pressure test on the vessel after 10
years, depending on general levels of wear
and tear.
A "qualified person" should be well informed
about Ordinance on Industrial Safety and
Health (formerly authorised expert)
Contact any of our approved service part-
ners. Most of our service partners have em-
ployees with expert qualifications.
The papers accompanying the vessel are
approval documents and must be kept
throughout the service life of the vessel.
These specifications only apply in Germa-
ny. Equivalent regulations apply in other
countries.