8 VENTILATION SYSTEM
(PREPARING OVEN FOR INSTALLATION)
This microwave oven/hood is designed for adaptation to three
types of hood ventilation systems. Select the type required
for your installation.
RECIRCULATING — non-vented, ductless.
Follow installation procedure (A). Recirculating requires
the use of the Charcoal Filter, which has already been
installed in the oven.
HORIZONTAL EXHAUST — outside ventilation.
Follow installation procedure (B).
VERTICAL EXHAUST — outside ventilation.
Follow installation procedure (C).
(A) RECIRCULATING:
1. The unit is shipped assembled for recirculating.
2. The Exhaust Damper Assembly is not required for
recirculating exhaust.
3. Charcoal Filter, included with the unit, is required for
recirculating exhaust. Attach the Charcoal Filter to the
upper side of the oven by sliding into the tabs. See
Figure 6. The Charcoal Filter should be replaced every 6
to 12 months, depending on use.
Tabs
Fan Cover Bracket
Back of
Oven
All manuals and user guides at all-guides.com
INSTALLATION INSTRUCTIONS
NON-VENTED, DUCTLESS OPERATION
Tabs
Figure 6
Figure 7
(B) HORIZONTAL EXHAUST:
1. Remove and save 2 screws from back edge and 1 screw
from the top center of Fan Cover Bracket. Remove Fan
Cover Bracket by sliding it in the opposite direction of the
arrow on the Fan Cover Bracket, as shown in Figure 7.
2. Withdraw Hood Fan Unit carefully and slip wires out of
Wire Box. See Figure 8.
CAUTION: Do not pull or stretch hood fan wiring.
3. Rotate the Hood Fan Unit and turn end-over-end so that
the fan blade openings are facing the back of the oven.
Replace Hood Fan Unit into the oven. Be careful not to
pinch the lead wire between the inner bracket and the
Hood Fan Unit. See Figure 9.
4. Put the lead wire into Wire Box. See Figure 10.
5. Replace the Fan Cover Bracket by sliding it into the slits
in the same direction as the arrow on the Fan Cover
Bracket. Make sure the fan blades are visible through
the rear openings in the oven before proceeding. Attach
Fan Cover Bracket to unit with 3 screws, which were
removed in Step 1 above. See Figure 11. The Hood Fan
Unit is now rotated for horizontal exhaust operation.
6. Attach the Exhaust Damper Assembly to the back of the
unit. See Figure 10. Use two Tapping Screws 4 x 8 from
the INSTALLATION HARDWARE and tighten into place.
E4
OUTSIDE VENTILATION
Figure 8
Figure 9