These caps are used to prevent water leakage when taking off the control box without draining
the water. Please refer to below instructions:
1. Use the wrench to take off the water outlet and inlet covers from the spa tub inner wall, then screw
the water outlet & inlet caps on and tighten. (pic 1 )
2. Separate the control box and spa tub by screwing off connection nuts.
3. Then screw the air inlet cap onto air pipe and tighten. Please make sure the gasket is on its place
to avoid water leakage. (pic 2)
NOTE:
1. Please make sure to unplug the power pack from the electrical receptacle before above actions.
2. In order to ensure proper work, please take off all caps when re-installing the control box.
Storage and Preparation for Future Use
1. Drain and clean the spa by following the "Drainage" and "Spa Cleaning" sections.
2. Refer to the instructions to deflate the spa tub and air bladder.
3. Make sure all the spa components and accessories are thoroughly clean and
dry before storage. Air-dry the spa tub in the mild sun for an hour before folding.
4. Fold the spa tub loosely and avoid any sharp corners to prevent damage or
leakage to the spa liner.
5. Prepare new additional cartridge for next time use.
6. Store the spa and accessories in a dry, temperature-controlled environment,
between 0°C and 40°C (32°F - 104°F). We recommend storing the spa with
desiccant.
7. The original packaging is recommended for storage.
8. After long-term storage, fill the spa with clean water and sanitizer, and turn on the
FILTER for at least 1 hour before use.
DISPOSAL AND ENVIRONMENTAL PROTECTION
This marking indicates that the product should not be disposed of with other household waste. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle the product responsibly to promote the sustainable reuse of
material resources. Information on disposal can be obtained from your local authorities.
To return your used device, please use the return and collection systems or contact the retailer where the product was purchased for
environmentally safe recycling.
TROUBLESHOOTING
ERROR CODE CHART
LED READING
Signal wire is loose
- - - / 888 / EEP
Communication failed
Water temperature is below 0°C (32°F) or exceeds 50°C (122°F)
F0
Temperature sensor failure
F1 immediately shows after pressing FILTER , HEATING or UVC
F1
F1 shows 15s after pressing FILTER, HEATING or UVC
CAUSE
19
pic 2
®
SOLUTION
Contact local MSpa Service Center
Contact local MSpa Service Center
Change the water
Contact local MSpa Service Center
Clean the parts and tubes that the water goes through
1. Add more water to the minimum line
2. Clean the parts and tubes that water goes through
3. Contact local MSpa Service Center