Porter Cable RN175C Manual De Instrucciones página 4

Clavadora para techado a resorte
Idiomas disponibles

Idiomas disponibles

English
PORTER-CABLE tools are precision-built tools, designed
for precise, high volume nailing. These tools will deliver
efficient, dependable service when used correctly and with
care. As with any fine power tool, for best performance
the manufacturer's instructions must be followed. Please
study this manual before operating the tool and understand
the safety warnings and cautions. The instructions on
installation, operation and maintenance should be read
carefully, and the manual kept for reference.
nOTE: Additional safety measures may be required
because of your particular application of the tool. Contact
your PORTER-CABLE representative or distributor with any
questions concerning the tool and its use.
PORTER-CABLE, 701 E. Joppa Road, Towson, Maryland
21286, U.S. & Canada Only.
PORTER-CABLE tools have been engineered to provide
excellent customer satisfaction and are designed to achieve
maximum performance when used with precision PORTER-
CABLE fasteners engineered to the same exacting standards.
PORTER-CABlE cannot assume responsibility for
product performance if our tools are used with
fasteners or accessories not meeting the specific
requirements established for genuine PORTER-CABlE
nails, staples and accessories.
Limited Warranty
U.s. and Canada Only
PORTER-CABLE warrants to the original retail purchaser
that the product purchased is free from defects in material
and workmanship, and agrees to repair or replace, at
PORTER-CABLE's option, any defective PORTER-CABLE
branded pneumatic stapler or nailer for a period of seven
(7) years from date of purchase [one (1) year from the date
Coil Roofing Nailer: RN175C
Tool specifications
Model
Length
Height
RN175C
10.51"
10.28"
(267 mm)
(261 mm)
All dimentions in inches unless otherwise specified.
Fastener specifications
Model
Fastener
Diameter
RN175C
15˚ coil
0.120"
roofing nails
(3 mm)
Tool Air Fitting: This tool uses a 1/4" N.P.T. male plug.
The inside diameter should be .275" (7 mm) or larger. The
fitting must be capable of discharging tool air pressure
when disconnected from the air supply. A 3/8" (9.5 mm)
male quick connector coupling is available from PORTER-
CABLE and may be used when a 1/4" (6.4 mm) supply line
is not available.
nOTE: A 3/8" (9.5 mm) supply line (and fittings) are required
for maximum tool performance.
2
Width
Weight
4.72"
5.34 lbs
(120 mm)
(2.42 kg)
Fastener Range
Loading
Capacity
3/4"–1-3/4"
120 nails
(19 mm–44.5 mm)
of purchase for compressors and tools used in production
applications]. Warranty is not transferable. Proof of purchase
date required. This warranty covers only damage resulting
from defects in material or workmanship; it does not cover
conditions or malfunctions resulting from normal wear,
neglect, abuse, accident or repairs attempted or made by
other than our national repair center or authorized warranty
service centers. Driver blades, bumpers, o-rings, pistons
and piston rings are considered normally wearing parts. For
optimal performance of your PORTER-CABLE tool always use
genuine PORTER-CABLE fasteners and replacement parts.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO THE IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. PORTER-
CABLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES.
Some states and countries do not allow limitations on how
long an implied warranty lasts, or the exclusion or limitation
of incidental or consequential damages, so the above
limitations or exclusions may not apply to you. This warranty
gives you specific legal rights, and you may also have other
rights which vary from state to state and country to country.
To obtain warranty service in the U.S. return the product,
together with proof of purchase, to the U.S. PORTER-CABLE
National or Regional Independent Authorized Warranty
Service Center. In the U.S. you may call us at
or visit www.portercable.com for the location most
convenient for you. In Canada please call us at
or visit www.portercable.com
Operating Pressure: 70-120 p.s.i.g (5 to 8.5 kg/cm²/4.8
to 8.3 bar). Select the operating pressure within this range
for best fastener performance. DO NOT EXCEED THIS
RECOMMENDED OPERATING PRESSURE.
Air Consumption: The RN175C requires 4.13 cubic feet per
minute (100 liters per minute) of free air to operate at the
rate of 100 fasteners per minute, at 80 p.s.i. (5.6 kg/cm
the actual rate at which the tool will be run to determine
the amount of air required. For instance, if your fastener
usage averages 50 fasteners per minute, you need 50% of
the tool's c.f.m. of free air which is required to operate the
tool at 100 fasteners per minute.
Trigger: The RN175C is equipped with a contact trigger.
Refer to the Actuating Tool section for more information.
Safety Information

WARNING: ALWAYS use safety glasses. Everyday
eyeglasses are NOT safety glasses. Also use face or
dust mask if cutting operation is dusty. ALWAYS WEAR
CERTIFIED SAFETY EQUIPMENT:
ANSI Z87.1 eye protection (CAN/CSA Z94.3),
ANSI S12.6 (S3.19) hearing protection,
NIOSH/OSHA/MSHA respiratory protection.
). Take
2