WARNING
• All U.S. models are designed for a 3-wire system connection. The dryer frame is
grounded to the neutral conductor at the terminal block. A 4-wire system connection
is required for new or remodeled construction, mobile homes, or if local codes do not
permit grounding through neutral. If you use the 4-wire system, you cannot ground the
dryer frame to the neutral conductor at the terminal block.
• Remove the terminal block cover plate. Insert the power cord with a UL-listed strain
relief through the hole provided in the cabinet near the terminal block.
• A strain relief must be used. Do not loosen the nuts already installed on the terminal
block. Be sure they are tight. Use a 3/8" (1 cm) deep well socket.
STEP 4 Connect the water hose
The dryer must be connected to a cold water tap using the provided water hoses.
Untitled-2 29
1. Close the cold water tap. If you have a
washer's cold water hose attached to
the cold water tap, unscrew and remove
the hose. Then, connect the female end
of the Y-connector to the cold water
tap.
2. Connect the straight end of the water
hose to the Y-connector. Tighten the
hose coupling by hand.
3. Using pliers, tighten the coupling an
additional two-thirds turn. Do not
overtighten. You can damage the
coupling.
English 29