Pioneer KURO PRO-FPJ1 Manual De Instrucciones página 46

Idiomas disponibles

Idiomas disponibles

Others
6
RS-232C Communication Examples
This section shows the communication examples of RS-232C.
Operating command
Type
Connection check
Power (On)
Power (Off)
Input (COMP.)
Remote Control
(MENU)
Gamma table
(User)
Gamma coefficient
(1.8)
Gamma data
(R)
Test pattern
(Staircase)
46
All manuals and user guides at all-guides.com
Command
PC
This unit: 21 89 01 00 00 0A
This unit
PC: 06 89 01 00 00 0A
PC
This unit: 21 89 01 50 57 31 0A
This unit
PC: 06 89 01 50 57 0A
PC
This unit: 21 89 01 50 57 30 0A
This unit
PC: 06 89 01 50 57 0A
PC
This unit: 21 89 01 49 50 32 0A
This unit
PC: 06 89 01 49 50 0A
PC
This unit: 21 89 01 52 43 37 33 32 45 0A
This unit
PC: 06 89 01 52 43 0A
PC
This unit: 21 89 01 47 54 34 0A
This unit
PC: 06 89 01 47 54 0A
PC
This unit: 21 89 01 47 50 30 0A
This unit
PC: 06 89 01 47 50 0A
PC
This unit: 21 89 01 47 52 0A
This unit
PC: 06 89 01 47 52 0A
PC
This unit: 512 bytes of gamma data
This unit
PC: 06 89 01 47 52 0A
PC
This unit: 21 89 01 54 53 36 0A
This unit
PC: 06 89 01 54 53 0A
Description
Checks connection
When power is turned on from standby mode
When power is turned off (standby mode)
from power-on mode
When video input is set to component
When the same operation as pressing the
[MENU] button on the remote control is made
When switched to "User"
When set to "1.8"
When the red gamma data is set
When staircase (gray) is set
loading