The opening must be constructed so that
it will not be obstructed from inside or
outside, or constructed close to the floor�
The opening is recommended to be on the
side opposite to that on which the flue gases
are discharged�
•
Avoid placing cabinetry directly above
cooktop when possible� If cabinetry is used
above cooking surface, use cabinet no more
than 13" deep�
•
Working areas adjacent to the cooktop
should have a 18" minimum clearance
between countertop and cabinet bottom�
Make sure the wall coverings, countertop and
cabinets around the cooktop can withstand
heat (up to 200°F) generated by the cooktop�
•
Maintain 30" minimum clearance between cooktop surface and cabinets installed above the cooktop�
- If a range hood is installed above the cooktop, it is important that the 30" minimum clearance between
the cooktop and bottom of the range hood is maintained� The range hood must be connected directly
to flues or to the outside�
- A range hood with minimum 350 CFM that projects at least 5" beyond front of cabinets can reduce risk
of burns caused by reaching over heated surface units�
GAS AND ELECTRICAL SUPPLY REQUIREMENTS
Installation must comply with local codes� In the absence of local codes, the gas cooktop must comply with the
National Fuel Gas Code ANSI Z223�1- latest edition in the United States, or in Canada CAN/CGA b149�1 and CAN/
CGA b149�2 and the National Electrical Code ANSI/NFPA No�70 – latest edition in United States, or in Canada CSA
Standard C22�1, Canadian Electrical Code, Part 1, and local code requirements�
Gas Supply Requirements
The gas supply should be located near the opening for
this cooktop and a minimum of 1" from the back wall� This
cooktop is manufactured for natural gas and is designed
to operate at 5" water column pressure� The regulator is
required to provide a minimum of 6" water column to a
maximum of 14" water column to the cooktop regulator�
Electrical Supply Requirements
The electric spark ignition feature for this model requires
a 120V electrical power supply and should be located 12"
below the countertop and within reach of the cooktops
four-foot power cord�
13�0"
(330 mm)
max�
30�0" (762 mm) min�
12�0" (305 mm)
Gas Supply
Line
8
figure 4
18�0" (457 mm)
min�
figure 5
1�0" (26 mm) min�