ELECTRIC SAFETY
An electric shock can be a source of a direct or indirect, or even fatal, serious accident.
Never touch the live parts of the torch as it is connected to the cutting circuit.
Do not touch the torch and the ground clamp at the same time.
Always use dry, well-maintained clothing to isolate yourself from the cutting circuit. Wear insulating shoes, no matter where you work.
PRECAUTION FOR USE
Never wrap the cutting leads around your body.
Do not use the cables or torch to move the machine.
The torch must be fully uncoiled to prevent overheating.
Switch off the generator after the torch is cooled and before each maintenance and before replacing or control wearing parts.
Regularly check the condition of the torch. If damaged, the torch must be replaced.
GENERAL DESCRIPTION
SPECIFICATIONS
The TPT torches are intended to the
SET UP
Designation
Reference
Length
Ignition voltage
Maximal rated current
Operating factor to 40°C
Gas type
Torch cooling mode
Room temperature range for cutting
Ambient temperature range for transport or storage
Switch trigger voltage
Applied standard
Electrode cross-section
Type of connector on the product side
Compatibility with plasma cutter
Inlet Pressure Range
INSTALLATION
TORCH CONNECTION REQUIREMENT
The generator must previsouly be powered off.
Insert the torch's connector (A) in the female compartment (E) and screw the B part. Be careful to tighten the torch.
To remove the torch, unscrew in the same manner as above.
TPT 25 - TPT 35 - TPT 40
manual PLASMA cutting process.
TPT 40
060753
40 A
60% (40 A)
-10 -> +40°C
-10 -> +55°C
EN IEC 60974-7 : 2019
4 mm²
IPT connector
EASYCUT 30 FV
EASYCUT 40
CUTTER 45CT
2.5 > 6.5 bars
Torch connector TPT40 (IPT)
1
8
2
3
7
4
6
5
Pins 1 and 2 : Switch
Pins 4 and 6 : Pilot arc
EN
TPT 25
TPT 35
068087
080775
4 m
500 V
25 A
35% (25 A)
air
air
24 V
2.5 mm²
4 mm²
Minifit
EASYCUT K25
EASYCUT K35
EASYCUT 25
PFC
Torch connector TPT 25 / TPT 35
(MINIFIT)
1
8
2
3
7
4
6
5
Pins 1 and 2 : Switch
Pins 4 and 6 : Pilot arc