TECHNICAL DATA
BATTERY-LAMP
Lightning time with one fully charged battery (4.0 Ah)
High Level ............................................................................
Med Level ............................................................................
Low Level ............................................................................
Luminous fl ux
High Level ............................................................................
Med Level ............................................................................
Low Level ............................................................................
Colour rendering index (CRI)..................................................
Colour temperature.................................................................
Battery voltage........................................................................
Weight according EPTA-Procedure 01/2014 (2.0 Ah) ............
Weight according EPTA-Procedure 01/2014 (6.0 Ah) ............
Protection class ......................................................................
WARNING Read all safety warnings and all
instructions. Failure to follow the warnings and instructions
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Remove the battery pack before starting any work on the
appliance.
Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors off er to
retrieve old batteries to protect our environment.
Do not store the battery pack together with metal objects
(short circuit risk).
Use only compatible Milwaukee chargers from the same
battery platform for charging battery packs. Do not use
battery packs from other systems.
Battery acid may leak from damaged batteries under
extreme load or extreme temperatures. In case of contact
with battery acid wash it off immediately with soap and
water. In case of eye contact rinse thoroughly for at least 10
minutes and immediately seek medical attention.
Warning: Do not direct the light beam at persons or animals
and do not stare into the light beam yourself (not even from
a distance). Staring into the light beam may result in serious
injury or vision loss.
Don't use this tool in wet areas .
The light source of this luminaire is not replaceable; when
the light source reaches its end of life the whole luminaire
shall be replaced.
Warning! To reduce the risk of fi re, personal injury, and
product damage due to a short circuit, never immerse your
tool, battery pack or charger in fl uid or allow a fl uid to fl ow
inside them. Corrosive or conductive fl uids, such as
seawater, certain industrial chemicals, and bleach or bleach
containing products, etc., can cause a short circuit.
SPECIFIED CONDITIONS OF USE
The Battery-lamp is intendend to be used light independent
use away from mains supply.
Do not use this product in any other way as stated for
normal use.
BATTERIES
Battery packs which have not been used for some time
should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure
to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept
clean.
14
ENGLISH
M12 AL
..........................3,5 h
..........................7,5 h
...........................15 h
.......................1000 lm
.........................400 lm
.........................200 lm
...........................80
.......................4000 K
...........................12 V
..........................1,2 kg
..........................1,6 kg
............................ IP54
For an optimum life-time, the battery packs have to be fully
charged, after used.
To obtain the longest possible battery life remove the battery
pack from the charger once it is fully charged.
For battery pack storage longer than 30 days:
Store the battery pack where the temperature is below 27°C
and away from moisture
Store the battery packs in a 30% - 50% charged condition
Every six months of storage, charge the pack as normal.
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Transportation of those batteries has to be done in
accordance with local, national and international provisions
and regulations.
• The user can transport the batteries by road without
further requirements.
Commercial transport of Lithium-Ion batteries by third
parties is subject to Dangerous Goods regulations.
Transport preparation and transport are exclusively to be
carried out by appropriately trained persons and the process
has to be accompanied by corresponding experts.
When transporting batteries:
• Ensure that battery contact terminals are protected and
insulated to prevent short circuit.
• Ensure that battery pack is secured against movement
within packaging.
• Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice
MAINTENANCE
The light source of this luminaire is not replaceable; when
the light source reaches its end of life the whole luminaire
shall be replaced.
Use only Milwaukee accessories and spare parts. Should
components need to be replaced which have not been
described, please contact one of our Milwaukee service
agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the machine type printed as well as the six-digit
No. on the label and order the drawing at your local service
agents or directly at: Techtronic Industries GmbH,
Max-Eyth-Straße 10, 71364 Winnenden, Germany.
SYMBOLS
CAUTION! WARNING! DANGER!
Do not stare at the operating light source.
Please read the instructions carefully before
starting the machine.
Do not dispose electric tools, batteries/rechargeable
batteries together with household waste material.
Electric tools and batteries that have reached the end
of their life must be collected separately and returned
to an environmentally compatible recycling facility.
Check with your local authority or retailer for recycling
advice and collection point.
Class III Electrical Protection
This tool is only suitable for indoor use. Never
expose tool to rain.
European Conformity Mark
British Confomity Mark
Ukraine Conformity Mark
EurAsian Conformity Mark
ENGLISH
15
loading