INSTALL THE UNIT (
3 . Lift the unit until contact is made between the unit
flange and cabinet . Secure the unit to the cabinet using
4 no . 8 x 5/8" wood screws included in parts bag (2
screws per side) . Use upper or lower holes (1, 2, 3, 4, 5
or 6) (FIG . 25) .
The Ease of Install Hooks TEMPORARILY hold the
unit in place . The unit MUST BE secured to the
cabinet using the included 4 screws .
Never use this unit as a shelf .
h
orizontal exhauSt inStallation only
4 . From inside the unit, slide the 3¼" x 10" adapter/damper
in the horizontal duct, then attach it to the unit using
aluminum duct tape all around the joint (FIG . 26) . Ensure
the damper opens as shown in damper side view .
5 . Insert the blower with its support plate inside the unit,
where the back plate was initially (A) . Attach to the unit
using 2 nuts previously removed in step 7 on page 12 (B)
(FIG . 27) .