HURAKAN ICF35DX4 Manual De Instrucciones página 17

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
EN
CONNECTION TO POWER SUPPLY MAINS
This cooker can be operated with connection of power supply, 380 V or 220 V. Initially, the
cooker is completed with the corresponding power cable and is adjusted for connection to
the power supply mains with a voltage of 380 V. To this effect, it is sufficient to connect all
three phases, neutral, and grounding to the switches corresponding by load. Or it is possible
to use the "plug socket–plug" pair corresponding by load for connection.
For connection to 220 V mains, make sure that the internal wiring in the room and other
connecting power supply lines are designed for the cooker load. In selecting the cable cross-
sectional area, be guided by the table given below. In addition, it is necessary to carefully
undo the lower cover of the cooker, dismantle the cable, connect the power cables
corresponding by load to the terminal box, pass them through the cover, put it in place and
screw it back.
Important: These connection operations should be carried out only by a skilled
specialist!