Provide adequate ventilation for toxic exhaust gases and
cooling air flow.
Do not start or run the generator in an enclosed area,
even if door or windows are open.
Engines give off carbon monoxide, an odorless, colorless,
poison gas.
Breathing carbon monoxide can cause nausea, fainting or
death.
APPLYING LOAD
This unit has been pretested and adjusted to handle its full
capacity. When starting the generator, disconnect all load.
Apply load only after generator is running. Voltage is
regulated via the engine speed adjusted at the factory for correct
output. Readjusting will void warranty.
When applying a load, do not exceed the maximum wattage
rating of the generator when using one or more receptacles.
Also, do not exceed the amperage rating of any one
receptacle.
English
Do not apply heavy electrical load during break-in period (the
first two to three hours of operations).
SHUTTING THE GENERATOR OFF
1.
Remove entire electrical load.
2.
Let the engine run for two minutes without load.
3.
Move the engine switch to the "OFF" position.
4.
Do not leave the generator until it has completely
stopped.
5.
Close the fuel shut off valve if the engine is to be put in
storage or transported.
6.
If a cover is used, do not install until unit has cooled.
7.
If the generator will not be used again for an extended
time period, refer to the SERVICE AND STORAGE
section of this manual.