Everbilt EFLS15CI-HD Manual De Instrucciones página 7

Idiomas disponibles

Idiomas disponibles

Electrical Settings
WARNING: Disconnect power before working on the pump, motor, pressure switch, or wiring.
CAUTION: The motor may be hot. Allow the motor to cool for 20 minutes after shut down.
CAUTION: Water pressure may have built up in the pump, pipes, or tank. Drain water to relieve pressure.
MOTOR VOLTAGE SETTINGS
Motors are designed to run on either 115 volt or 230 volt power.
Ensure the motor's wiring is set to match the voltage being
supplied to your motor from the electrical source.
Remove the plate screws and the motor cover plate from the motor
end cover. Wire the pump according to the diagram to the right.
WIRING THE PUMP FOR THE INCORRECT VOLTAGE WILL
Wiring Connections
WARNING: Risk of electric shock. Can shock, burn, or kill.
1.
To avoid dangerous or fatal electrical shock, turn OFF power to the motor before working on electrical
connections.
2.
Ground the motor before connecting to electrical power supply. Failure to ground the motor can cause severe or
fatal electrical shock hazard.
3.
Supply voltage must be within +/- 10% of the nameplate voltage. Incorrect voltage can cause fire or damage the
motor and voids the warranty. If in doubt consult a licensed electrician.
4.
Use a wire size specified in the Wiring Chart (below). If possible, connect the pump to a separate branch circuit
with no other appliances on it.
5.
Do not ground to a gas supply line.
6.
Wire the motor according to the
7.
If the diagram on the motor cover plate differs fr om the diagrams in this section, follow the diagram on the
motor cover plate.
8.
If this procedure or the wiring diagrams are confusing, consult a licensed electrician.
RECOMMENDED WIRE AND FUSE SIZES FOR 115 AND 230 VOLTS
MAX. LOAD
MOTOR HP
VOLTS
1-1/2
115/230 20.09/10.05
DAMAGE THE PUMP.
diagram on the motor cover plate.
BRANCH FUSE
AWG MIN. WIRE
AMP
RATING AMP
SIZE (mm
30/15
10/14 (5.5/2)
115V 60Hz
Plate Screws
DISTANCE IN FEET FROM MOTOR TO SUPPLY
0-100
101-200
2
)
6/14 (14/2)
8/14 (8.4/2)
7
Please contact 1-844-883-1872 for further assistance.
Hot
LINE 1
To Breaker
BLUE
WHITE
Neutral
LINE 2
To Breaker
230V 60Hz
GREEN
GROUND
Motor Cover Plate
201-300
301-400
2
AWG WIRE SIZE (mm
)
6/12 (14/3) 4/10 (21/5.5) 4/10 (21/5.5)
Hot
LINE 1
To Breaker
BLUE
WHITE
Hot
LINE 2
To Breaker
GREEN
GROUND
401-500
HOMEDEPOT.COM