Installation (continued)
11 . A UL listed or CSA approved conduit connector must be provided
at each end of the power supply cable .
12 . Wire size must conform to all local codes and ordinances . The
latest edition requirements of the National Electrical Code ANSI/
NFPA 70, or the latest edition CSA Standards C22.1-94, Canadian
Electrical Code Part 1 and C22.2 No. 0-M91.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
Installation work and electrical wiring must be
FOLLOWING:
done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
DANGER: Risk of electrical shock . This ventilation fan must be
properly grounded .
DANGER: Turn off the power circuit breaker or the power switch
on the junction box before installing this unit . Touching circuitry
inside the ventilation fan while it is energized will result in
death or serious injury .
DANGER: All electrical wiring must be properly installed,
insulated, and grounded . Improper insulation and grounding
will result in deadly electrical shock .
IMPORTANT:
It is the customer's responsibility to contact a qualified electrical
installer and assure that the electrical installation is adequate and complies with
the National Electrical Code, or CSA standards, as well as all local codes and
ordinances.
- Install a cable clamp (not supplied) to the wiring hole of the fan
housing. See figure 9.
- Feed the electrical supply cable through the cable clamp . See
figure 9.
- Use UL approved connectors to connect the fan wires to your
electrical supply cable as shown in figure 10.
- Tighten the cable clamp to secure the electrical supply cable .
- Reinstall the electrical wiring junction cover to the fan housing
ensuring all wiring connections are fully enclosed. See figure 11.
ON/OFF Switch
(Not Supplied)
Switch Box
120 VAC Line In
Electrical Wiring
Junction Cover
9
Please contact [email protected] or 1-877-333-0098 for further assistance .
Feed electrical
supply cable
Fig . 9
Cable Clamp
Fan Housing
Fig . 10
Fig . 11
CONGLOMKB .COM
= Black
= White
= Ground (Bare)
Fan Housing