IR8-DT8 - User's manual
IMPULSE-COUNTER
! If the number of impulses is programmed to one, the active detector quickly also the exit OUT
(opening of the contacts), and it signals the revelation to antitheft central.
If the number of programmed impulses is greater of one, the red LED with a flash indicate the first
!
revelation then remains interdicted for about two seconds.
If it persists the state of revelation movement for over 2 seconds ,the red LED repeats the signalling
!
and the sensor counts a new impulse
When the number of signallings impulse reaches the programmed number, the red LED is
ignited fixed and opens contact OUT in order to signal the alarm to antitheft central.
NOTE : After about 15 seconds from detection, the pulse count is reset.
ON
1 Impulse
SW1=OFF
SW2=OFF
SWITCH1/SWITCH2 position dip-switch according to the desired value
ON
SW4=ON (activated exclusion)
EXCLUSION LED SIGNALLING
!
The dip switch 4 active on and off the signalling alarms and detection of the LEDs :
SW=ON esclude; SW=OFF included.
ALARM MEMORY
!
This feature allows you to identify which sensor generated an alarm.
Connecting the memory "M" input with at the exit "+int" of antitheft central.
NOTE: When you reinsert the central the LED flashes for 5 seconds after which the alarm memory is
leared
! SUMMARY OPERATING LED
Red LED: applying the power supply comes on for about 30 seconds during the stabilization phase
=
of the circuit.
Yellow LED:it is ignited in order to signal the activity of detection of the infrared
=
Green LED: it is ignited in order to signal the activity of detection of the section to microwave.
=
=
Red LED operation (alarm memory)
=
! Slow flashing (5 sec.): insertion of antitheft central
! Fast flashing: reporting of revelation of the sensor with active alarm memory.
! Lit fixed: signalling of the detection of the sensor without active memory alarm.
4
ON
2 Impulses
SW1=OFF
SW2=ON
ON
3 Impulses
SW1=ON
SW2=OFF
ON
SW4=OFF (disactivated exclusion)
security
ON
4 Impulses
SW1=ON
SW2=ON