CLEANING AND MAINTENANCE
Warning!
Pull the power plug before doing any cleaning and maintenance work
on the appliance.
Warning!
Wait until the compressor has completely cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying out any cleaning and
maintenance work.
Never clean the machine and its components with solvents, flammable
or toxic liquids. Us only a damp cloth making sure you have unplugged
the compressor from the current outlet.
After approx. 2 hours of use, the condensate that has formed must be
drained from the receiver. First of all, vent all the air using the
accessory connected, as described above.
The condensation water must be drained off each day by opening the drain
valve (on the bottom of the pressure vessel).
Warning!
If the water that condenses is not drained, it may corrode the
receiver, reducing its capacity and impairing safety.
As it is a contaminating product, condensate must be DISPOSED of
in accordance with laws on protection of the environment and current
legislation.
The compressor must be disposed in conformity with the methods
provided for by local regulations.
5
POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
Reduction of performance. Frequent start-up.
Low pressure values.
The compressor stops and restarts
automatically after a few minutes.
After a few attempts to restart, the compressor.
The compressor does not stop and the safety
valve is tripped.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts. Tampering with the machine may impair
its safety and in any case make the warranty null and void.
Warranty and repair.
In the event of defective goods or requirements for spare parts, kindly contact us.
NOTIBER0011_MULTI_01-2023_C
CAUSE
Excessive performance request, check for any
leaks from the couplings and/or pipes. Intake
filter may be clogged.
Tripping of the thermal cutout due to
overheating of the motor.
Tripping of the thermal cutout due to
overheating of the motor (removal of the
plug with the compressor running, low power
voltage).
Irregular functioning of the compressor or
breakage of the pressure switch.
REMEDY
Replace the seals of the fitting, clean or replace
the filter.
Clean the air ducts in the conveyor. Ventilate
the work area.
Activate the on/off switch. Ventilate the work
area. Wait a few minutes. The compressor will
restart independently. Remove any power cable
extensions.
Remove the plug and contact the Service
Center.
G
B
7
ENGLISH