Dea NET230N Instrucciones De Uso Y Advertencias página 39

Ocultar thumbs Ver también para NET230N:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 131
5 ELECTRICAL CONNECTIONS
Execute the wiring following the directions of table 1 and diagrams.
WARNING For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separate
from 230V ~ power wires (minimum 4 mm in air or 1 mm via supplementary insulation) placing them in plastic raceways and securing
them with adequate clamps near terminal boards.
WARNING For connection to the mains, use a multipolar cable having a minimum section 3x1,5 mm² and complying with the current
regulations. For connecting the motors, use a minimum cross section 1,5 mm² cable and complying with the current regulations. As
an example, if the cable is out side (outdoor), must be at least equal to H07RN-F, whereas if it (in a raceway), must be at least equal to
H05VV-F.
WARNING All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequently
eliminate any excess.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm
1-2
230 V ~ ±10% (50/60 Hz) power supply input
3-4-5
Operator 1 output 230 V ~ max 500W (max 600W if only one motor)
6-7-8
Operator 2 output 230 V ~ max 500W (if present)
9-10
230 V ~ max 150 W output for open gate fi x warning light (if P052=0) or courtesy light (if P052>1)
11-12
Flashing light output 230 V ~ max 40W
"Boost" output for electric-lock, max 1 x art. 110 (if P062=0), 24V pulse output, max 5W (if P062=1), step
13 (-)
by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output for electric-lock
13-14
power supply via external relay (if P062=4), output for electro-magnets power supply for barriers (if P062=5)
14 (+)
or temporized output (if P062>5).
Output 24V
15-16
a 24V (if set FL) or as a Warning output (if set WL).
Warning: the output capacity allows to use LED fl ashing lights only.
18 - IN_6
Input 6
19 - Com
20 - IN_5
Input 5
21 - Com
22 - IN_4
Input 4
23 - Com
24 - IN_3
Input 3
25 - Com
26 - IN_2
Input 2
27 - Com
28 - IN_1
Input 1
29 - Com
-
Aerial signal input
-
Ground aerial input
31-32
24 V ~ power supply output for auxiliary devices
33 (+)
33-34
24 V
34 (-)
Table 1 "terminal board connections"
max 100mA; by selecting the FL/WL jumper, you can get a clone of the 230 Flash output as
TYPE 00
TYPE 01
(FCC 1)
(STOP)
N.C.
N.C.
(FCA 1)
(PHOTO 2)
N.C.
N.C.
( PHOTO 1)
(PHOTO 1)
N.C.
N.C.
(SAFETY)
(SAFETY)
N.C.
N.C.
(PED.)
(PED.)
N.O.
N.O.
(START)
(START)
N.O.
N.O.
power supply output for controlled safety devices
TYPE 02
TYPE 03
If unused, short circuit
(NONE)
(NONE)
N.O.
N.O.
(NONE)
(NONE)
N.O.
N.O.
(STOP)
(NONE)
N.C.
N.O.
(SAFETY)
(NONE)
N.C.
N.O.
(PHOTO 1)
(PHOTO 1)
N.C.
N.C.
(START)
(START)
N.O.
N.O.
2
.
TYPE 04
TYPE 05
(FCC 1)
(FCC 1)
N.C.
N.C.
(FCA 1)
(FCA 1)
N.C.
N.C.
(STOP)
(PHOTO 1)
N.C.
N.C.
(NONE)
(SAFETY)
N.O.
N.C.
(PHOTO 1)
(CLOSE)
N.C.
N.O.
(START)
(OPEN)
N.O.
N.O.
(AUX + ST)
=
max 200mA
EN-5
loading