Storage; Cleaning And Care - Qlima PGF 1211 Instrucciones De Uso

Ocultar thumbs Ver también para PGF 1211:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
regulator to the new cylinder
Check that the regulator seal is correctly fitted and able to fulfil its function.
Perform leak test using soapy water solution.
WARNING: only change the gas cylinder in a amply ventilated area, away
from any ignition source (candle, cigarettes, other flame producing applianc-
es, ...).

STORAGE

Make sure the heater is in off position
Always close the valve of the gas cylinder after use or in case of a distur-
bance.
Disconnect the gas container from the gas heater.
Store the gas container in a well-ventilated room. Position it far away from
inflammable, explosive or hot materials and preferably not in the home. In
addition it should never be stored in the basement or attic.
Cylinder must be stored out of the reach of children.
Disconnected cylinder must have threaded valve plugs tightly installed and
must not be stored in garage or any other enclosed area. Only store in venti-
lated area!
Storage of heater indoors is permissible only if the cylinder is disconnected
and removed from the heater.
Check the tightness of the connections of the gas line supply (gas cylinder
valve / regulator, regulator/hose, hose/appliance inlet). If you suspect a dam-
age, have it changed by your gas dealer.
Never store liquid gas cylinder in a sub-terrain, or at places without adequate
air ventilation.

CLEANING AND CARE

Warning: Make sure the heaer is in off position and is cool!
Warning: Do not clean heater with cleaners that are combustible or corrosive.
Wipe off powder coated surfaces with soft, moist rag and soap water.
Remove debris, spider and insect nests from ventilation opening of the cylin-
der enclosure, control compartment, burner and circulation air passageways
of the heater with heavy duty pipe cleaner or compressed air to keep appli-
ance clean and safe for use.
Never clear ports or other openings with toothPic.ks or other article that will
break and block the ports.
If carbon deposits develop, remove the reflector and flame screen and clean
them with soap water.
Do not paint the flame screen, control panel or reflector.
Cover the burner unit with the optional supplied protective cover when the
heater is not in use. Wait until the heater is cool before covering.
In a salt-air environment, such as near an ocean, corrosion occurs more
quickly than normal. Check frequently for corroded areas and repair them
promptly.
4
71
Tabla de contenido
loading

Tabla de contenido