Installations
Installations Cautions
When installing the water heater, it should leave a certain amount of space (at least 300mm)
to facilitate future maintenance. If the water heater is embedded in the gusset plate during
installation, the gusset plate near the maintenance cover side should be movable to facilitate
disassembling the maintenance cover during maintenance.
It should ensure that the inlet pressure of tap water is not less than 0.05MPa and the
maximum pressure does not exceed 0.75MPa.
Electric water heater should be installed indoors, where the ambient temperature is above
0°C. The pipeline should be centrally arranged. The hot water outlet should not be too far
from the use place of hot water. If it exceeds eight meters, the hot water pipeline should be
insulated to reduce the heat loss.
The wall where the water heater is hung should be sturdy and secure to withstand four times
the weight of the water heater after filling with water. If it is a non-bearing wall or hollow brick
wall, it is necessary to take appropriate protective measures, add brackets, use crossing
screws, and install back boards.
The installation location of the electric water heater should be selected a place that is
convenient to use, maintain and have a floor drain. If the water tank or water pipe leaks, it
will not cause damage to nearby or lower level facilities. The installation position try to avoid
installing on the toilet, bathtub, washbasin and door frame. So that it does not create a
feeling of overwhelming or insecurity for the user.
Do not reverse the inlet and outlet pipes. The safety valve should be installed in the
designated position and should not be altered privately. The pressure relief hole of safety
valve should be kept in contact with atmosphere. Do not block it.
For security, water heaters should use independent sockets (multifunctional sockets are
prohibited) and be reliably earthed. And the quality of the socket should be in line with local
national standards. It is strictly forbidden to use the water heater without reliable earthed.
The power outlet of the water heater should be placed in a dry place where water cannot
shower, so as not to affect the normal work of the machine (preferably with a waterproof
box).
Use an electroprobe to measure whether the live wire and neutral wire are connected in
reverse. After confirming that the machine has been filled with water, the joints do not leak
and the power supply meets the requirements, then it can be heated by electricity.
For avoiding the danger of accidental reset of the over-temperature thermostat, the water
heater must not be powered by external switching devices such as timers. It shall not be
connected to a circuit that is frequently switched on and off through other settings.
In order to prevent the occurrence of accidents, the accessories provided by our company
must be installed and must not be replaced or substituted by yourself. If the accessories are
damaged, it must be notified to our Maintenance Department for repair and replacement
with the accessories provided by our company. If the above matters are not complied with,
we will not be responsible for any direct or indirect loss caused by the accident.
7