5/8" Washer
(supplied)
Shim Under
Washer
(not supplied)
6.
Place the (4) 3/8" lag screws
through the air compressor feet,
washers, shims, and into the
anchors.
7.
Torque 3/8" lag screws to
7 - 10 ft. lbs.
Wiring instructions
product may void its warranty and
your fire insurance. Have circuit wiring
performed by qualified personnel
such as a licensed electricians who
is familiar with the current national
electrical code and any prevailing local
electrical codes. Une mauvaise
connexion électrique de ce produit
pourrait annuler la garantie et votre
assurance contre les incendies.
A qualified electrician needs to knows
the following before wiring:
1.
The amperage rating of the electri-
cal box should be adequate. Refer
to the Specification Chart for this
information.
2.
The supply line should have the
same electrical characteristics
(voltage, cycle, phase) as the
motor. Refer to the motor name-
plate, on side of motor, for this
information.
NOTE: The wiring must be the same
as the motor nameplate voltage plus
or minus 10%. Refer to local codes for
recommended wire sizes, correct wire
size, and maximum wire run; undersize
wire causes high amp draw and over-
heating to the motor.
3/8" Lag
Screw
(not supplied)
Surface Line
Concrete Anchor
(not supplied)
Improper electrical
installation of this
wiring must be located away from
hot surfaces such as manifold
assembly, compressor outlet tubes,
heads, or cylinders.
GROUNDING INSTRUCTIONS
This product should be connected to
a metallic, permanent wiring system,
of an equipment-grounding terminal
or lead on the product.
Voltage and Circuit Protection
Refer to the specification chart for the
voltage and minimum branch circuit
requirements.
air compressors can be operated
on a 15 amp circuit if the following
conditions are met.
1.
Voltage supply to circuit must
comply with the National
Electrical Code.
2.
Circuit is not used to supply any
other electrical needs.
3.
Extension cords comply with
specifications.
4.
Circuit is equipped with a 15 amp
circuit breaker or 15 amp time
delay fuse. NOTE: If compressor
is connected to a circuit protect-
ed by fuses, use only time delay
fuses. Time delay fuses should be
marked "D" in Canada and "T" in
the US.
If any of the above conditions cannot
be met, or if operation of the com-
pressor repeatedly causes interruption
of the power, it may be necessary to
operate it from a 20 amp circuit. It is
not necessary to change the cord set.
Air Distribution System
pipe is not designed for use with
compressed air. Regardless of its
indicated pressure rating, plastic
pipe can burst from air pressure.
Use only metal pipe for air
distribution lines.
11 - ENG
Risk of Electrical
Shock. Electrical
Risk of Unsafe
Operation. Certain
Risk of Bursting.
Plastic or PVC
N004083